Monitoring Ethylene Oxide Residues in Food: A Simplified QuEChERS-Based GC-MS/MS Method for Routine Analysis
Molecules · 05.06.2026 · 31 (11) · 1978
DOI: 10.3390/molecules31111978 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 05.06.2026. Verfasst von Tabita Mauti und 12 weiteren Autor:innen. Beteiligte Einrichtung: Istituto Zooprofilattico Sperimentale del Lazio e della Toscana M. Aleandri, Via Appia Nuova 1411, 00178 Rome, Italy. Hauptthemen laut MEDLINE: Gas Chromatography-Mass Spectrometry, Food Contamination, Tandem Mass Spectrometry, Food Analysis. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Ethylene oxide (EtO) has been banned in the European Union since 1991 as a fumigant for food commodities. Nevertheless, recurrent contamination incidents, especially since 2020, involving imports from India, have raised significant food safety concerns. Despite regulatory measures, EtO and its metabolite, 2-chloroethanol (2-CE), continue to be detected in a variety of food products, including dried foods, dietary supplements, and food additives. This study presents a QuEChERS-based method involving the conversion of EtO into 2-CE, which is subsequently quantified by isotope dilution gas chromatography–tandem mass spectrometry (GC-MS/MS). In contrast to previously published methods, this protocol utilises an Agilent HP-5ms Ultra Inert column (30 m × 250 μm × 0.25 mm), routinely employed in our laboratory for multi-residue pesticide analysis. The proposed approach is therefore readily adaptable to laboratories already performing multi-residue analyses, as it does not require modifications to existing instrumental configurations. The method was validated in accordance with SANTE/11312/2021 guidelines. A total of 84 samples, primarily imported from India, as well as from Brazil, Argentina, and the United Kingdom, were analysed. 2-CE was detected in four samples, and in two cases, the sum of EtO and 2-CE, expressed as EtO, exceeded the European Union (EU) maximum residue limit (MRL).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Istituto Zooprofilattico Sperimentale del Lazio e della Toscana M. Aleandri, Via Appia Nuova 1411, 00178 Rome, Italy.
- School of Specialisation in Food Science, Tor Vergata University of Rome, 00133 Rome, Italy.
ORCID-Profile: Daniela Delfino, Valentina Nicolini, Francesca D'Onofrio, Katia Russo
Zitieren
APA
Mauti, T., Delfino, D., Nicolini, V., Droghei, B., Colangelo, D., Triolone, D., Fiorucci, F., Di Giustino, P., Mancuso, M., Leo, M., D'Onofrio, F., Ubaldi, A., & Russo, K. (2026). Monitoring Ethylene Oxide Residues in Food: A Simplified QuEChERS-Based GC-MS/MS Method for Routine Analysis. Molecules, 31(11), 1978. https://doi.org/10.3390/molecules31111978
Vancouver
Mauti T, Delfino D, Nicolini V, Droghei B, Colangelo D, Triolone D, et al. Monitoring Ethylene Oxide Residues in Food: A Simplified QuEChERS-Based GC-MS/MS Method for Routine Analysis. Molecules. 2026;31(11):1978. doi:10.3390/molecules31111978
BibTeX
@article{Mauti2026,
author = {Mauti, Tabita and Delfino, Daniela and Nicolini, Valentina and Droghei, Barbara and Colangelo, Daniele and Triolone, Daniela and Fiorucci, Fulvia and Di Giustino, Paolo and Mancuso, Marta and Leo, Marianna and D'Onofrio, Francesca and Ubaldi, Alessandro and Russo, Katia},
title = {Monitoring Ethylene Oxide Residues in Food: A Simplified QuEChERS-Based GC-MS/MS Method for Routine Analysis},
journal = {Molecules},
year = {2026},
volume = {31},
number = {11},
pages = {1978},
doi = {10.3390/molecules31111978}
}
EUVIMED