EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous Determination of Aromatic Amines in Tattoo Ink by Gas Chromatography–Electron Ionization (GC-EI)–Mass Spectrometry (MS) and Tandem MS (MS/MS)

Eunyoung Shin, Hyebeen Kim, Jihye Choi, Minjae Kang, Juhui Shin, Sangwon Cha iD

Molecules · 12.05.2026 · 31 (10) · 1623

DOI: 10.3390/molecules31101623 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 12.05.2026. Verfasst von Eunyoung Shin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Dongguk University, Seoul 04620, Republic of Korea. Hauptthemen laut MEDLINE: Ink, Tandem Mass Spectrometry, Gas Chromatography-Mass Spectrometry, Amines. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aromatic amines (AAs) are potent carcinogens found in tattoo inks that pose significant health risks. Precise quantitative analysis is essential for safety. In this study, we developed and validated a robust method for the simultaneous quantification of 21 regulated AAs using both gas chromatography–electron ionization (GC-EI)–mass spectrometry (MS) and tandem MS (MS/MS). After optimizing separation conditions, MS-based selected ion monitoring (SIM) and MS/MS-based multiple reaction monitoring (MRM) were evaluated. While both methods were largely sufficient to ensure compliance with international safety thresholds, the MRM-based approach exhibited superior detection capability with comparable analytical accuracy and precision, providing a more effective tool for trace-level hazardous compound analysis. The developed MRM method was applied to eight commercial tattoo inks, identifying five AAs in five products. Notably, o-toluidine, o-anisidine, and 3,3′-dichlorobenzidine significantly exceeded the regulatory limit (5.0 mg/kg), particularly in green and yellow inks. The dual-capability GC-MS platform—combining high-performance MRM quantification with robust spectral confirmation—ensures the high throughput and analytical confidence necessary for regulatory compliance and public health protection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InkTandem Mass SpectrometryGas Chromatography-Mass SpectrometryAminesTattooingReproducibility of Results

Stichwörter der Autor:innen

aromatic aminesgas chromatographymass spectrometrytandem mass spectrometrytattoo inks

Substanzen

Amines

Autor:innen und Institutionen

  • Department of Chemistry, Dongguk University, Seoul 04620, Republic of Korea.

ORCID-Profile: Sangwon Cha

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Shin, E., Kim, H., Choi, J., Kang, M., Shin, J., & Cha, S. (2026). Simultaneous Determination of Aromatic Amines in Tattoo Ink by Gas Chromatography–Electron Ionization (GC-EI)–Mass Spectrometry (MS) and Tandem MS (MS/MS). Molecules, 31(10), 1623. https://doi.org/10.3390/molecules31101623

Vancouver

Shin E, Kim H, Choi J, Kang M, Shin J, Cha S. Simultaneous Determination of Aromatic Amines in Tattoo Ink by Gas Chromatography–Electron Ionization (GC-EI)–Mass Spectrometry (MS) and Tandem MS (MS/MS). Molecules. 2026;31(10):1623. doi:10.3390/molecules31101623

BibTeX
@article{Shin2026,
  author = {Shin, Eunyoung and Kim, Hyebeen and Choi, Jihye and Kang, Minjae and Shin, Juhui and Cha, Sangwon},
  title = {Simultaneous Determination of Aromatic Amines in Tattoo Ink by Gas Chromatography–Electron Ionization (GC-EI)–Mass Spectrometry (MS) and Tandem MS (MS/MS)},
  journal = {Molecules},
  year = {2026},
  volume = {31},
  number = {10},
  pages = {1623},
  doi = {10.3390/molecules31101623}
}
Kostenlos starten →