EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Efficiency Assessment of Fenton-Based Pre-Treatment of Medical Wastewater Using Fe, Cu, and Mn Catalysts—Impact on the Aquatic Environment

Andrzej R Reindl iD, Maciej Tankiewicz iD, Agnieszka Fiszka Borzyszkowska iD, Lidia Wolska

Molecules · 23.03.2026 · 31 (6) · 1060

DOI: 10.3390/molecules31061060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 23.03.2026. Verfasst von Andrzej R Reindl und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Toxicology, Faculty of Health Sciences, Medical University of Gdansk, 80-210 Gdansk, Poland. Hauptthemen laut MEDLINE: Wastewater, Iron, Water Pollutants, Chemical, Hydrogen Peroxide. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education in Poland.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the efficiency and ecotoxicological impact of the Fenton oxidation process with different metal-based catalysts (FeSO4, CuSO4, MnSO4) in removing pharmaceuticals and organic contaminants from real hospital wastewater. All catalytic systems achieved high oxidation, with COD reduction reaching 81–89% after 4 h. Two complementary approaches were applied: targeted LC-MS/MS quantification of a model mixture of antibiotics and pharmaceuticals, and untargeted GC-MS/MS screening method for assessing the overall organic contaminant profile. Toxicity was assessed using Microtox®. Targeted analysis showed complete or near-complete degradation of β-lactams, tetracyclines and most sulfonamides, with slightly lower removal for sulfamethoxazole in FeSO4 system (96%). Fluoroquinolones and selected pharmaceuticals, such as caffeine and propranolol were more resistant, particularly with CuSO4 and MnSO4 catalysts. The untargeted GC-MS/MS screening revealed the highest overall reduction in chromatographic peak areas for FeSO4 (70%), followed by MnSO4 (39%) and CuSO4 (36%). GC-MS/MS profiling confirmed that the Fe-catalyzed process was the most effective in reducing the total chromatographic peak area (70%). However, ecotoxicological assays revealed a significant increase in toxicity post-treatment, with growth inhibition of Allivibrio fischeri reaching 98%. This suggests that high oxidation does not directly correlate with biological safety, likely due to the presence of unconsumed reagents or the formation of transformation products with higher acute toxicity. These findings emphasize the necessity of integrating bioassays into treatment evaluation protocols to assess the true environmental risk of treated effluents.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WastewaterIronWater Pollutants, ChemicalHydrogen PeroxideCopperManganeseWater PurificationCatalysisOxidation-ReductionTandem Mass SpectrometryAnimalsGas Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

Fenton oxidationecotoxicity bioassaysenvironmental risk assessmentmedical wastewaterpharmaceutical removal

Substanzen

WastewaterIronWater Pollutants, ChemicalHydrogen PeroxideCopperManganeseFenton's reagent

Autor:innen und Institutionen

  • Department of Environmental Toxicology, Faculty of Health Sciences, Medical University of Gdansk, 80-210 Gdansk, Poland.

ORCID-Profile: Andrzej R Reindl, Maciej Tankiewicz, Agnieszka Fiszka Borzyszkowska

Förderung

  • Ministry of Science and Higher Education in Poland

Zitieren

APA

Reindl, A. R., Tankiewicz, M., Fiszka Borzyszkowska, A., & Wolska, L. (2026). Efficiency Assessment of Fenton-Based Pre-Treatment of Medical Wastewater Using Fe, Cu, and Mn Catalysts—Impact on the Aquatic Environment. Molecules, 31(6), 1060. https://doi.org/10.3390/molecules31061060

Vancouver

Reindl AR, Tankiewicz M, Fiszka Borzyszkowska A, Wolska L. Efficiency Assessment of Fenton-Based Pre-Treatment of Medical Wastewater Using Fe, Cu, and Mn Catalysts—Impact on the Aquatic Environment. Molecules. 2026;31(6):1060. doi:10.3390/molecules31061060

BibTeX
@article{Reindl2026,
  author = {Reindl, Andrzej R and Tankiewicz, Maciej and Fiszka Borzyszkowska, Agnieszka and Wolska, Lidia},
  title = {Efficiency Assessment of Fenton-Based Pre-Treatment of Medical Wastewater Using Fe, Cu, and Mn Catalysts—Impact on the Aquatic Environment},
  journal = {Molecules},
  year = {2026},
  volume = {31},
  number = {6},
  pages = {1060},
  doi = {10.3390/molecules31061060}
}
Kostenlos starten →