Efficiency Assessment of Fenton-Based Pre-Treatment of Medical Wastewater Using Fe, Cu, and Mn Catalysts—Impact on the Aquatic Environment
Molecules · 23.03.2026 · 31 (6) · 1060
DOI: 10.3390/molecules31061060 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 23.03.2026. Verfasst von Andrzej R Reindl und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Toxicology, Faculty of Health Sciences, Medical University of Gdansk, 80-210 Gdansk, Poland. Hauptthemen laut MEDLINE: Wastewater, Iron, Water Pollutants, Chemical, Hydrogen Peroxide. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education in Poland.
Abstract (Originalsprache)
This study evaluated the efficiency and ecotoxicological impact of the Fenton oxidation process with different metal-based catalysts (FeSO4, CuSO4, MnSO4) in removing pharmaceuticals and organic contaminants from real hospital wastewater. All catalytic systems achieved high oxidation, with COD reduction reaching 81–89% after 4 h. Two complementary approaches were applied: targeted LC-MS/MS quantification of a model mixture of antibiotics and pharmaceuticals, and untargeted GC-MS/MS screening method for assessing the overall organic contaminant profile. Toxicity was assessed using Microtox®. Targeted analysis showed complete or near-complete degradation of β-lactams, tetracyclines and most sulfonamides, with slightly lower removal for sulfamethoxazole in FeSO4 system (96%). Fluoroquinolones and selected pharmaceuticals, such as caffeine and propranolol were more resistant, particularly with CuSO4 and MnSO4 catalysts. The untargeted GC-MS/MS screening revealed the highest overall reduction in chromatographic peak areas for FeSO4 (70%), followed by MnSO4 (39%) and CuSO4 (36%). GC-MS/MS profiling confirmed that the Fe-catalyzed process was the most effective in reducing the total chromatographic peak area (70%). However, ecotoxicological assays revealed a significant increase in toxicity post-treatment, with growth inhibition of Allivibrio fischeri reaching 98%. This suggests that high oxidation does not directly correlate with biological safety, likely due to the presence of unconsumed reagents or the formation of transformation products with higher acute toxicity. These findings emphasize the necessity of integrating bioassays into treatment evaluation protocols to assess the true environmental risk of treated effluents.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Environmental Toxicology, Faculty of Health Sciences, Medical University of Gdansk, 80-210 Gdansk, Poland.
ORCID-Profile: Andrzej R Reindl, Maciej Tankiewicz, Agnieszka Fiszka Borzyszkowska
Förderung
- Ministry of Science and Higher Education in Poland
Zitieren
APA
Reindl, A. R., Tankiewicz, M., Fiszka Borzyszkowska, A., & Wolska, L. (2026). Efficiency Assessment of Fenton-Based Pre-Treatment of Medical Wastewater Using Fe, Cu, and Mn Catalysts—Impact on the Aquatic Environment. Molecules, 31(6), 1060. https://doi.org/10.3390/molecules31061060
Vancouver
Reindl AR, Tankiewicz M, Fiszka Borzyszkowska A, Wolska L. Efficiency Assessment of Fenton-Based Pre-Treatment of Medical Wastewater Using Fe, Cu, and Mn Catalysts—Impact on the Aquatic Environment. Molecules. 2026;31(6):1060. doi:10.3390/molecules31061060
BibTeX
@article{Reindl2026,
author = {Reindl, Andrzej R and Tankiewicz, Maciej and Fiszka Borzyszkowska, Agnieszka and Wolska, Lidia},
title = {Efficiency Assessment of Fenton-Based Pre-Treatment of Medical Wastewater Using Fe, Cu, and Mn Catalysts—Impact on the Aquatic Environment},
journal = {Molecules},
year = {2026},
volume = {31},
number = {6},
pages = {1060},
doi = {10.3390/molecules31061060}
}
EUVIMED