Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 16.03.2026. Verfasst von Blaž Hodnik und 2 weiteren Autor:innen. Beteiligte Einrichtung: Krka d.d., R&D, Šmarješka Cesta 6, 8001 Novo Mesto, Slovenia. Hauptthemen laut MEDLINE: Serum Albumin, Bovine, Chromatography, Gel, Mass Spectrometry. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Slovenian Research and Innovation Agency, Krka d.d., Slovenian Research Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring peptide and protein self-association is essential for understanding biological function, formulation stability, and aggregation mechanisms. While size-exclusion chromatography (SEC) is routinely used to quantify protein-size variants under native conditions, its hyphenation to high-resolution mass spectrometry (HRMS) for simultaneous structural characterization remains limited. Here, we report the development and validation of a robust SEC-UV/HRMS method optimized for native-like analysis of bovine serum albumin (BSA) monomers and higher-order oligomers using standard-flow electrospray ionization. Systematic evaluation of source parameters, mobile-phase composition, and chromatographic conditions enabled retention of native BSA structure, minimized in-source unfolding, and enhanced MS sensitivity, allowing detection of oligomers up to the heptamer. A short, narrow-bore 200 Å UHPLC SEC separation column was used. Low-flow separations (~0.05 mL/min) enabled efficient ionization and 10 min run times. An accelerated 60 °C stress-testing protocol demonstrated that SEC-MS can semi-quantitatively monitor oligomerization dynamics, complementing UV-based quantification and revealing transient species not resolved by UV alone. The method showed acceptable linearity, precision, and sample stability, and comparison with SEC-RALS/LALS confirmed molecular-weight trends across aggregation states. Overall, the developed SEC-UV/HRMS workflow provides a rapid, sensitive, and widely accessible approach for UV-based quantification of monomer- and HRMS-based characterizing protein aggregation in research and quality control in pharmaceutical laboratories.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Serum Albumin, BovineChromatography, GelMass SpectrometryCattleAnimalsSpectrometry, Mass, Electrospray IonizationChromatography, High Pressure Liquid

Stichwörter der Autor:innen

high-resolution mass spectrometryproteinssize exclusion chromatography

Substanzen

Serum Albumin, Bovine

Autor:innen und Institutionen

  • Krka d.d., R&D, Šmarješka Cesta 6, 8001 Novo Mesto, Slovenia.
  • Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna Pot 113, 1000 Ljubljana, Slovenia.

ORCID-Profile: Blaž Hodnik

Förderung

  • The Slovenian Research and Innovation Agency
  • Krka d.d.
  • Slovenian Research Agency

Zitieren

APA

Hodnik, B., Čamič, Ž., & Pompe, M. (2026). Development and Validation of SEC-UV/HRMS Procedure for Simultaneous Determination of BSA and Its Association Products. Molecules, 31(6), 1001. https://doi.org/10.3390/molecules31061001

Vancouver

Hodnik B, Čamič Ž, Pompe M. Development and Validation of SEC-UV/HRMS Procedure for Simultaneous Determination of BSA and Its Association Products. Molecules. 2026;31(6):1001. doi:10.3390/molecules31061001

BibTeX
@article{Hodnik2026,
  author = {Hodnik, Blaž and Čamič, Žiga and Pompe, Matevž},
  title = {Development and Validation of SEC-UV/HRMS Procedure for Simultaneous Determination of BSA and Its Association Products},
  journal = {Molecules},
  year = {2026},
  volume = {31},
  number = {6},
  pages = {1001},
  doi = {10.3390/molecules31061001}
}
Kostenlos starten →