EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Investigating Variability in Metabolomics: A Comparative Study of Analytical Platforms and Blood Matrices Using HPLC-HRMS

Giulia Guerra iD, Alessio Polymeropoulos iD, Elisabetta Venturelli iD, Veronica Huber iD, Francesco Segrado iD, Daniele Morelli iD, Sabina Sieri iD

Molecules · 28.02.2026 · 31 (5) · 814

DOI: 10.3390/molecules31050814 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Molecules, online erschienen am 28.02.2026. Verfasst von Giulia Guerra und 6 weiteren Autor:innen. Beteiligte Einrichtung: Epidemiology and Prevention Unit, Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, 20133 Milan, Italy. Hauptthemen laut MEDLINE: Metabolomics, Liquid Chromatography-Mass Spectrometry, Metabolome. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero della Salute, Italian Ministry of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Untargeted metabolomics faces significant challenges in standardization due to variability introduced by sample preparation and analytical workflows. We systematically evaluated the impact of biological matrices, extraction protocols, and chromatographic configurations to establish a mechanism-informed framework aimed at improving reproducibility in large-scale clinical and epidemiological studies. Three extraction protocols were compared using an in-house pooled heparin plasma: monophasic protein precipitation with isopropanol (IPA), methanol:acetonitrile (MeOH:ACN), and a modified Matyash biphasic method. The most reproducible protocol was then applied to four blood matrices. Samples were analysed using untargeted metabolomics on hydrophilic interaction liquid chromatography (HILIC) and reversed-phase (RP) HPLC columns, with mass spectrometry data processed using Compound Discoverer. Both IPA and MeOH:ACN extractions achieved over 80% of features with coefficient of variation (CV%) ≤ 30% for both RP and HILIC, whereas the Matyash method showed higher variability, with a larger proportion of metabolites exhibiting CV% > 30%. Across matrices, RP chromatography detected over 80% of metabolites with CV% < 30%, while HILIC showed higher variability, with at least 20% of metabolites above this threshold. Among matrices, serum and heparin plasma outperformed EDTA and citrate in reproducibility. We propose a standardized workflow in which monophasic extractions combined with RP chromatography maximize reproducibility and metabolite coverage, minimizing methodological artefacts and providing a reliable framework for robust biological discovery in large-scale untargeted metabolomics studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MetabolomicsLiquid Chromatography-Mass SpectrometryMetabolomeHumansChromatography, High Pressure LiquidReproducibility of ResultsHeparinMass SpectrometryHydrophobic and Hydrophilic Interactions

Stichwörter der Autor:innen

blood matrixdata qualityhuman plasmametabolomicsvalidation

Substanzen

Heparin

Autor:innen und Institutionen

  • Epidemiology and Prevention Unit, Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, 20133 Milan, Italy.
  • Biostatistics for Clinical Research, Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, 20133 Milan, Italy.
  • Nutrition Research and Metabolomics Unit, Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, 20133 Milan, Italy.
  • Unit of Translational Immunology, Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, 20133 Milan, Italy.
  • Laboratory Medicine Department, Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, 20133 Milan, Italy.

ORCID-Profile: Giulia Guerra, Alessio Polymeropoulos, Elisabetta Venturelli, Veronica Huber, Francesco Segrado, Daniele Morelli, Sabina Sieri

Förderung

  • Ministero della Salute
  • Italian Ministry of Health

Zitieren

APA

Guerra, G., Polymeropoulos, A., Venturelli, E., Huber, V., Segrado, F., Morelli, D., & Sieri, S. (2026). Investigating Variability in Metabolomics: A Comparative Study of Analytical Platforms and Blood Matrices Using HPLC-HRMS. Molecules, 31(5), 814. https://doi.org/10.3390/molecules31050814

Vancouver

Guerra G, Polymeropoulos A, Venturelli E, Huber V, Segrado F, Morelli D, et al. Investigating Variability in Metabolomics: A Comparative Study of Analytical Platforms and Blood Matrices Using HPLC-HRMS. Molecules. 2026;31(5):814. doi:10.3390/molecules31050814

BibTeX
@article{Guerra2026,
  author = {Guerra, Giulia and Polymeropoulos, Alessio and Venturelli, Elisabetta and Huber, Veronica and Segrado, Francesco and Morelli, Daniele and Sieri, Sabina},
  title = {Investigating Variability in Metabolomics: A Comparative Study of Analytical Platforms and Blood Matrices Using HPLC-HRMS},
  journal = {Molecules},
  year = {2026},
  volume = {31},
  number = {5},
  pages = {814},
  doi = {10.3390/molecules31050814}
}
Kostenlos starten →