Development and Validation of a Confirmatory LC-MS/MS Method Using QuEChERS for Determination of Nitrofuran Metabolites in Eggs According to EU Regulation 2021/808
Molecules · 17.02.2026 · 31 (4) · 700
DOI: 10.3390/molecules31040700 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 17.02.2026. Verfasst von Elmira Marku und 7 weiteren Autor:innen. Beteiligte Einrichtung: Food Safety and Veterinary Institute, Rr. Aleksandër Moisiu, Nr. 82, 2020 Tirana, Albania. Hauptthemen laut MEDLINE: Nitrofurans, Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Eggs. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Agency for Scientific Research and Innovation (AKKSHI), the Faculty of Natural Sciences at the University of Tirana, and the Food Safety and Veterinar…, National Agency for Scientific Research and Innovation (NASRI) in Albania, Food Safety and Veterinary Institute (ISUV), Albania.
Abstract (Originalsprache)
Nitrofurans are banned veterinary medicinal products due to their carcinogenic and mutagenic properties; however, their protein-bound metabolites (AOZ, AMOZ, AHD, SEM, and DNSAH) may persist in food-producing animals, particularly in eggs. Reliable confirmatory methods are therefore essential for residue monitoring under the stringent requirements of Commission Implementing Regulation (EU) 2021/808. This study reports the development and validation of a sensitive and selective LC–MS/MS method combining acid hydrolysis, 2-nitrobenzaldehyde derivatization, and QuEChERS extraction for the determination of nitrofuran metabolites in eggs. Chromatographic separation was carried out using a phenyl-hexyl column, and detection using a tandem mass spectrometer, supported by isotope-labeled internal standards, ensured robust identification and quantification. Linearity was satisfactory over the investigated concentration range (R2 > 0.99), with recoveries between 82 and 109%. The method’s precision was acceptable, with repeatability RSD values below 10% and within-laboratory reproducibility RSD values below 22%. Matrix effects were effectively controlled, remaining within ±20% following internal standard normalization. Decision limits (CCα) ranged from 0.29 to 0.37 µg/kg, well below the EU reference point for action of 0.5 µg/kg. The method’s performance was further confirmed through participation in an accredited proficiency test scheme. Overall, the validated method provides a reliable analytical tool for routine official control laboratories, enabling the sensitive confirmatory detection of banned nitrofuran residues in eggs and supporting food safety and regulatory compliance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Food Safety and Veterinary Institute, Rr. Aleksandër Moisiu, Nr. 82, 2020 Tirana, Albania.
- Chemistry Department, Faculty of Natural Sciences, University of Tirana, Bulevardi "Zogu I", Nr. 25, 1001 Tirana, Albania.
- Food Safety Department, Teagasc Food Research Centre, Ashtown, D15 DYO5 Dublin, Ireland.
- Novartis Pharma Albania & Kosovo & North Macedonia, 1001 Tirana, Albania.
ORCID-Profile: Elmira Marku, Kozeta Vaso, Martin Danaher, Erinda Pllaha, Suela Teqja, Jonida Canaj, Ina Pasho
Förderung
- National Agency for Scientific Research and Innovation (AKKSHI), the Faculty of Natural Sciences at the University of Tirana, and the Food Safety and Veterinar…
- National Agency for Scientific Research and Innovation (NASRI) in Albania
- Food Safety and Veterinary Institute (ISUV), Albania
- Teagasc
Zitieren
APA
Marku, E., Vaso, K., Danaher, M., Pllaha, E., Teqja, S., Canaj, J., Pasho, I., & Ajdini, I. (2026). Development and Validation of a Confirmatory LC-MS/MS Method Using QuEChERS for Determination of Nitrofuran Metabolites in Eggs According to EU Regulation 2021/808. Molecules, 31(4), 700. https://doi.org/10.3390/molecules31040700
Vancouver
Marku E, Vaso K, Danaher M, Pllaha E, Teqja S, Canaj J, et al. Development and Validation of a Confirmatory LC-MS/MS Method Using QuEChERS for Determination of Nitrofuran Metabolites in Eggs According to EU Regulation 2021/808. Molecules. 2026;31(4):700. doi:10.3390/molecules31040700
BibTeX
@article{Marku2026,
author = {Marku, Elmira and Vaso, Kozeta and Danaher, Martin and Pllaha, Erinda and Teqja, Suela and Canaj, Jonida and Pasho, Ina and Ajdini, Ilir},
title = {Development and Validation of a Confirmatory LC-MS/MS Method Using QuEChERS for Determination of Nitrofuran Metabolites in Eggs According to EU Regulation 2021/808},
journal = {Molecules},
year = {2026},
volume = {31},
number = {4},
pages = {700},
doi = {10.3390/molecules31040700}
}