EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous Quantification of Multiple Analytes in Rat Plasma by UHPLC–MS/MS Following Oral Administration of Gastrodiae Rhizoma Extract for Pharmacokinetic Evaluation

Lu Chen iD, Yameng Zhu iD, Huizi Ouyang iD, Xiwei Wu, Wenhan Lin, Kaili Zhang iD, Jun He iD

Molecules · 2025

DOI: 10.3390/molecules30224404 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2025. Verfasst von Lu Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Chinese Medicine Modernization, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Plant Extracts, Gastrodia, Rhizome. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gastrodiae Rhizoma (GR) is known to have a medicinal and food-based homology. It is used to treat infantile convulsion, epilepsy, spasm, tetanus, and vertigo. In this study, an ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated to quantify fourteen components (p-hydroxybenzyl alcohol, gastrodin, parishin E, p-hydroxybenzoic acid, parishin C, parishin A, parishin B, nicotinamide, p-hydroxybenzaldehyde, adenosine, 3,4-dihydroxybenzaldehyde, syringaldehyde, dauricine, and nobiletin) of GR in rat plasma. Methanol precipitation was used to prepare the samples with astragalin, serving as the internal standard. In multiple reaction monitoring (MRM) mode, the fourteen components were separated by gradient elution on a Waters ACQUITY UPLC® HSS T3 column. Under these conditions, all fourteen analytes’ calibration curves demonstrated strong linearity within wide concentration ranges (r > 0.9941). Accuracy for the intra-day and inter-day assessments ranged from −13.74% to 12.76%, and the precision for all analytes remained below 8.88%. The analytes’ extraction recoveries ranged from 66.78% to 114.2%, accompanied by matrix effects ranging from 63.65% to 117.61%. Under the evaluated conditions, stability tests confirmed that the compounds remained stable, with relative standard deviations below 13.83%. Consequently, the UHPLC-MS/MS method was effectively used to determine the pharmacokinetics of fourteen components in rat plasma after oral administration of GR extract. This study provides supportive data for rational application of GR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryPlant ExtractsGastrodiaRhizomeDrugs, Chinese HerbalAnimalsChromatography, High Pressure LiquidRatsAdministration, OralMaleRats, Sprague-DawleyReproducibility of Results

Stichwörter der Autor:innen

Gastrodiae Rhizoma extractUHPLC-MS/MSmedicine food homologypharmacokineticsrat plasma

Substanzen

Plant ExtractsDrugs, Chinese Herbal

Autor:innen und Institutionen

  • State Key Laboratory of Chinese Medicine Modernization, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China.

ORCID-Profile: Lu Chen, Yameng Zhu, Huizi Ouyang, Kaili Zhang, Jun He

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Chen, L., Zhu, Y., Ouyang, H., Wu, X., Lin, W., Zhang, K., & He, J. (2025). Simultaneous Quantification of Multiple Analytes in Rat Plasma by UHPLC–MS/MS Following Oral Administration of Gastrodiae Rhizoma Extract for Pharmacokinetic Evaluation. Molecules. https://doi.org/10.3390/molecules30224404

Vancouver

Chen L, Zhu Y, Ouyang H, Wu X, Lin W, Zhang K, et al. Simultaneous Quantification of Multiple Analytes in Rat Plasma by UHPLC–MS/MS Following Oral Administration of Gastrodiae Rhizoma Extract for Pharmacokinetic Evaluation. Molecules. 2025. doi:10.3390/molecules30224404

BibTeX
@article{Chen2025,
  author = {Chen, Lu and Zhu, Yameng and Ouyang, Huizi and Wu, Xiwei and Lin, Wenhan and Zhang, Kaili and He, Jun},
  title = {Simultaneous Quantification of Multiple Analytes in Rat Plasma by UHPLC–MS/MS Following Oral Administration of Gastrodiae Rhizoma Extract for Pharmacokinetic Evaluation},
  journal = {Molecules},
  year = {2025},
  doi = {10.3390/molecules30224404}
}
Kostenlos starten →