Negative Paper Spray Ionization Mass Spectrometry for the Determination of Endocrine-Disrupting Chemicals with Application to Paraben Analysis in Cosmetics

Seonyoung Cho, Sarmila Shrestha Amatya iD, Hyerin Bahng, Eungyeong Lee, Yunsang Ko, Sangwon Cha iD

Molecules · 2025

DOI: 10.3390/molecules30224356 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2025. Verfasst von Seonyoung Cho und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Dongguk University, Seoul 04620, Republic of Korea. Hauptthemen laut MEDLINE: Endocrine Disruptors, Parabens, Cosmetics, Spectrometry, Mass, Electrospray Ionization. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Paper spray ionization mass spectrometry (PSI-MS) enables rapid analysis with minimal sample preparation, yet negative-ion mode performance has been limited by poor sensitivity and unstable signals, similar to conventional electrospray ionization. In this study, we optimized negative PSI tandem MS (MS/MS) for twelve endocrine-disrupting chemicals (EDCs) and related biomarkers—including bisphenols, phthalates, parabens, and substituted phenols—used as model analytes. A systematic solvent and additive screen identified 1 mM ammonium fluoride in methanol and 0.1% ammonium hydroxide in 9:1 MeOH/carbon tetrachloride as optimal conditions, providing enhanced deprotonated-ion intensities and improved stability. Calibration curves generated under these conditions showed excellent linearity, with limits of quantitation (LOQs) in the low-ppb range. Application to cosmetic formulations demonstrated reliable paraben quantitation. In fortified hand cream, LOQs below 1 mg/kg were achieved, with recoveries of 93–110% and intra- and inter-day precision below 10% RSD. Notably, PSI-MS/MS performance was comparable to LC–MS/MS, without a separation step. These results demonstrate the feasibility of optimized negative PSI-MS as a sensitive and robust tool for paraben determination in cosmetics and highlight its potential as a versatile platform for broader EDC quantification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endocrine DisruptorsParabensCosmeticsSpectrometry, Mass, Electrospray IonizationTandem Mass SpectrometryPaperPhthalic AcidsLimit of DetectionPhenols

Stichwörter der Autor:innen

cosmeticsendocrine-disrupting chemicalspaper spray ionizationparabentandem mass spectrometry

Substanzen

Endocrine DisruptorsParabensCosmeticsPhthalic AcidsPhenols

Autor:innen und Institutionen

  • Department of Chemistry, Dongguk University, Seoul 04620, Republic of Korea.

ORCID-Profile: Sarmila Shrestha Amatya, Sangwon Cha

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Cho, S., Amatya, S. S., Bahng, H., Lee, E., Ko, Y., & Cha, S. (2025). Negative Paper Spray Ionization Mass Spectrometry for the Determination of Endocrine-Disrupting Chemicals with Application to Paraben Analysis in Cosmetics. Molecules. https://doi.org/10.3390/molecules30224356

Vancouver

Cho S, Amatya SS, Bahng H, Lee E, Ko Y, Cha S. Negative Paper Spray Ionization Mass Spectrometry for the Determination of Endocrine-Disrupting Chemicals with Application to Paraben Analysis in Cosmetics. Molecules. 2025. doi:10.3390/molecules30224356

BibTeX
@article{Cho2025,
  author = {Cho, Seonyoung and Amatya, Sarmila Shrestha and Bahng, Hyerin and Lee, Eungyeong and Ko, Yunsang and Cha, Sangwon},
  title = {Negative Paper Spray Ionization Mass Spectrometry for the Determination of Endocrine-Disrupting Chemicals with Application to Paraben Analysis in Cosmetics},
  journal = {Molecules},
  year = {2025},
  doi = {10.3390/molecules30224356}
}
Kostenlos starten →