A Novel Aptamer Selection Strategy for Pseudomonas aeruginosa and Its Application as a Detecting Probe in a Hybrid Lateral Flow Assay
Molecules · 2025
DOI: 10.3390/molecules30173499 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, 2025. Verfasst von Thu Thao Pham und 6 weiteren Autor:innen. Beteiligte Einrichtung: Vietnam Academy of Science and Technology, Graduate University of Science and Technology, Hanoi 100000, Vietnam. Hauptthemen laut MEDLINE: Pseudomonas aeruginosa, Aptamers, Nucleotide, SELEX Aptamer Technique. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Technology, Vietnam Ministry of Science and Technology.
Abstract (Originalsprache)
Pseudomonas aeruginosa is a clinically significant pathogen with high antibiotic resistance, necessitating rapid and reliable diagnostic methods. In this study, we developed a whole-cell aptamer selection method for P. aeruginosa using an Eppendorf-tube-based SELEX system, where bacterial cells were directly incubated with an ssDNA library. This configuration enhanced the recovery of bound aptamers and overcame the cell quantity limitations often encountered in microtiter-plate-based SELEX. After 10 selection rounds, six aptamer candidates were obtained and evaluated for affinity. Molecular docking analysis revealed that aptamer T1 possessed the highest target selectivity. To demonstrate diagnostic applicability, aptamer T1 was integrated into a hybrid lateral flow immunoassay (LFIA), replacing the conventional detection antibody. In this format, the AuNP–aptamer complex bound to the target bacteria and was captured by a specific antibody immobilized on the test line. The LFIA achieved a visual detection limit of 2.34 × 102 CFU/mL within 15 min, showing high specificity and suitability for point-of-care applications. This study presents the first demonstration of an aptamer–antibody hybrid LFIA for bacterial detection and highlights the potential of aptamers as low-cost, rapidly synthesized recognition elements adaptable for the detection of other infectious agents.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Vietnam Academy of Science and Technology, Graduate University of Science and Technology, Hanoi 100000, Vietnam.
- Vietnam-Korea Institute of Science and Technology, Hoa Lac Hi-Tech Park, Hanoi 100000, Vietnam.
- Institute of Tropical Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet Road, Hanoi 100000, Vietnam.
ORCID-Profile: Thu Thao Pham, Nguyen T T Huyen, T N Lien Truong, Nguyen Thi Phuong Trang
Förderung
- Ministry of Science and Technology
- Vietnam Ministry of Science and Technology
Zitieren
APA
Pham, T. T., T T Huyen, N., Hong Oanh, L., Dai Tran, L., Tran, H. V., Truong, T. N. L., & Thi Phuong Trang, N. (2025). A Novel Aptamer Selection Strategy for Pseudomonas aeruginosa and Its Application as a Detecting Probe in a Hybrid Lateral Flow Assay. Molecules. https://doi.org/10.3390/molecules30173499
Vancouver
Pham TT, T T Huyen N, Hong Oanh L, Dai Tran L, Tran HV, Truong TNL, et al. A Novel Aptamer Selection Strategy for Pseudomonas aeruginosa and Its Application as a Detecting Probe in a Hybrid Lateral Flow Assay. Molecules. 2025. doi:10.3390/molecules30173499
BibTeX
@article{Pham2025,
author = {Pham, Thu Thao and T T Huyen, Nguyen and Hong Oanh, Le and Dai Tran, Lam and Tran, Hiep V and Truong, T N Lien and Thi Phuong Trang, Nguyen},
title = {A Novel Aptamer Selection Strategy for Pseudomonas aeruginosa and Its Application as a Detecting Probe in a Hybrid Lateral Flow Assay},
journal = {Molecules},
year = {2025},
doi = {10.3390/molecules30173499}
}
EUVIMED