EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reversed-Phase (RP) and Hydrophilic Interaction (HILIC) Separation Mechanisms for the Assay of Nicotine and E-Cigarette Liquids

Răzvan Moisi, Mircea-Alexandru Comănescu iD, Andrei-Valentin Medvedovici iD

Molecules · 2025

DOI: 10.3390/molecules30163443 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2025. Verfasst von Răzvan Moisi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical & Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Ave. #90-92, 050663 Bucharest, Romania. Hauptthemen laut MEDLINE: Nicotine, Electronic Nicotine Delivery Systems, Chromatography, Reverse-Phase. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nicotine is a highly used addictive substance that has recently also become available through electronic cigarettes. Here we present a study of nicotine from e-cigarette liquids through reversed-phase (RP) and hydrophilic interaction (HILIC) liquid chromatography. Multiple aqueous mobile-phase additives are considered for the RP mechanism, focusing on chaotropic agents, mobile-phase concentrations and mixing ratios, and column temperature. Sample preparation was conducted by toluene liquid–liquid extraction of e-cigarette liquids diluted with aqueous 25 mM NaHCO3/Na2CO3. Optimal RP results for retention and peak symmetry were obtained using aqueous 0.1% formic acid and 20 mM ammonium hexafluorophosphate with 0.1% formic acid in acetonitrile, using a gradient profile with a C18 column, exploited at 40 °C and a 1.5 mL/min flow rate. A dilute-and-shoot alternative with automated flow reversal after isocratic elution is presented. For HILIC, aqueous 100 mM ammonium formate and 0.1% formic acid in acetonitrile were used as mobile-phase components, using a gradient profile, on a Thermo Scientific™ Acclaim™ Mixed-Mode HILIC-1 column, operated at 25 °C with a 1 mL/min flow rate. UV detection was at 260 nm. Absolute limits of quantitation in the 1 μg/mL range were obtained for all tested alternatives, with 1 μL injection volumes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NicotineElectronic Nicotine Delivery SystemsChromatography, Reverse-PhaseHydrophobic and Hydrophilic InteractionsLiquid-Liquid ExtractionChromatography, Liquid

Stichwörter der Autor:innen

HILICchaotropic agentsion pairingreversed phase

Substanzen

Nicotine

Autor:innen und Institutionen

  • Department of Analytical & Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Ave. #90-92, 050663 Bucharest, Romania.

ORCID-Profile: Mircea-Alexandru Comănescu, Andrei-Valentin Medvedovici

Zitieren

APA

Moisi, R., Comănescu, M. A., & Medvedovici, A. V. (2025). Reversed-Phase (RP) and Hydrophilic Interaction (HILIC) Separation Mechanisms for the Assay of Nicotine and E-Cigarette Liquids. Molecules. https://doi.org/10.3390/molecules30163443

Vancouver

Moisi R, Comănescu MA, Medvedovici AV. Reversed-Phase (RP) and Hydrophilic Interaction (HILIC) Separation Mechanisms for the Assay of Nicotine and E-Cigarette Liquids. Molecules. 2025. doi:10.3390/molecules30163443

BibTeX
@article{Moisi2025,
  author = {Moisi, Răzvan and Comănescu, Mircea-Alexandru and Medvedovici, Andrei-Valentin},
  title = {Reversed-Phase (RP) and Hydrophilic Interaction (HILIC) Separation Mechanisms for the Assay of Nicotine and E-Cigarette Liquids},
  journal = {Molecules},
  year = {2025},
  doi = {10.3390/molecules30163443}
}
Kostenlos starten →