EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Versatile High-Performance Liquid Chromatography and Ultraviolet Detection-Based Method for the Determination of Thioproline in Pharmaceutical and Cosmetic Products

Marta Gaweł, Martyna Płodzik, Rafał Głowacki iD, Justyna Piechocka iD

Molecules · 2025

DOI: 10.3390/molecules30153152 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2025. Verfasst von Marta Gaweł und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Chemistry, Faculty of Chemistry, University of Lodz, 163/165 Pomorska Str., 90-236 Łódź, Poland. Hauptthemen laut MEDLINE: Cosmetics, Thiazolidines. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Lodz.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The article presents the first method based on high-performance liquid chromatography and ultraviolet detection (HPLC-UV) for the determination of timonacic (thioproline, 1,3-thiazolidine-4-carboxylic acid, tPro) in pharmaceutical tablets and face care products (creams, sera, foundations, suncreams). Sample preparation primarily involves solid-liquid extraction (SLE) of tPro with 0.2 mol/L phosphate buffer pH 6, derivatization with 0.25 mol/L 2-chloro-1-methylquinolinium tetrafluoroborate (CMQT), followed by polytetrafluoroethylene (PTFE) membrane filtration. The chromatographic separation of the stable UV-absorbing 2-S-quinolinium derivative is achieved within 14 min at 25 °C on a Zorbax SB-C18 (150 × 4.6 mm, 5 µm) column using gradient elution. The eluent consists of 0.1 mol/L trichloroacetic acid (TCA), pH 1.7, in a mixture with acetonitrile (ACN) delivered at a flow rate of 1 mL/min. The analyte is quantified by monitoring at 348 nm. The assay linearity was observed within 0.5–125 μmol/L. The limit of quantification (LOQ) was found to be 0.5 μmol/L. The accuracy ranged from 93.22% to 104.31% and 97.38% to 103.48%, while precision varied from 0.30% to 11.23% and 1.13% to 9.64% for intra- and inter-assay measurements, respectively. The method was successfully applied to commercially available on the Polish market pharmaceutical and cosmetic products.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CosmeticsThiazolidinesChromatography, High Pressure LiquidReproducibility of ResultsSpectrophotometry, UltravioletLimit of DetectionPharmaceutical Preparations

Stichwörter der Autor:innen

1,3-thiazolidine-4-carboxylic acid2-chloro-1-methylquinolinium tetrafluoroboratecosmeticshigh performance liquid chromatographypharmaceutical tabletstimonacic

Substanzen

CosmeticsPharmaceutical PreparationsThiazolidines

Autor:innen und Institutionen

  • Department of Environmental Chemistry, Faculty of Chemistry, University of Lodz, 163/165 Pomorska Str., 90-236 Łódź, Poland.
  • Doctoral School of Exact and Natural Sciences, University of Lodz, 12/16 Banacha Str., 90-237 Łódź, Poland.

ORCID-Profile: Rafał Głowacki, Justyna Piechocka

Förderung

  • University of Lodz

Zitieren

APA

Gaweł, M., Płodzik, M., Głowacki, R., & Piechocka, J. (2025). Versatile High-Performance Liquid Chromatography and Ultraviolet Detection-Based Method for the Determination of Thioproline in Pharmaceutical and Cosmetic Products. Molecules. https://doi.org/10.3390/molecules30153152

Vancouver

Gaweł M, Płodzik M, Głowacki R, Piechocka J. Versatile High-Performance Liquid Chromatography and Ultraviolet Detection-Based Method for the Determination of Thioproline in Pharmaceutical and Cosmetic Products. Molecules. 2025. doi:10.3390/molecules30153152

BibTeX
@article{Gawe2025,
  author = {Gaweł, Marta and Płodzik, Martyna and Głowacki, Rafał and Piechocka, Justyna},
  title = {Versatile High-Performance Liquid Chromatography and Ultraviolet Detection-Based Method for the Determination of Thioproline in Pharmaceutical and Cosmetic Products},
  journal = {Molecules},
  year = {2025},
  doi = {10.3390/molecules30153152}
}
Kostenlos starten →