Rapid Enantiomeric Ratio Determination of Multiple Amino Acids Using Ion Mobility-Mass Spectrometry
Molecules · 06.06.2025 · 30 (12) · 2497
DOI: 10.3390/molecules30122497 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 06.06.2025. Verfasst von Wenqing Xu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Sorbonne Université, Faculté des Sciences et de l'Ingénierie, Institut Parisien de Chimie Moléculaire (IPCM), 75005 Paris, France. Hauptthemen laut MEDLINE: Amino Acids, Ion Mobility Spectrometry, Mass Spectrometry. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CHIRAMICS project, MetaboHUB.
Themen: Mobilisation
Abstract (Originalsprache)
Chiral analysis is becoming increasingly important across various scientific fields, including chemistry, pharmaceuticals, biosciences, and more recently, metabolomics. In this context, a high-resolution and high-throughput method was developed for the simultaneous determination of the enantiomeric ratio (er) of seven pairs of amino acid (AA) enantiomers (Arg, Gln, His, Met, Pro, Tyr, and Trp) using flow injection analysis coupled with ion mobility-mass spectrometry (FIA-IM-MS) technology. Specifically, the Single Ion Mobility Monitoring (SIM2) mode on a TIMS-TofTM instrument enabled the rapid relative quantification of chiral compound mixtures. A linear model accurately described the relationship between enantiomeric ratio and IM-MS response for Arg, Gln, and Pro enantiomers, as evidenced by high R2 values and unbiased residuals. In contrast, non-linear trends were observed for His, Tyr, and Trp, where a quadratic model significantly improved the fit. However, the linear model was retained for Met, despite an R2 of about 0.98, due to its comparable performance and simplicity. Measurement accuracy was confirmed with very good recovery rates for er values of 0.95 and 0.99 across all AAs. Finally, the potential of the FIA-SIM2-MS approach in chiral analysis was demonstrated, particularly its ability to provide a reliable and efficient high-throughput tool for accurate er determination.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Sorbonne Université, Faculté des Sciences et de l'Ingénierie, Institut Parisien de Chimie Moléculaire (IPCM), 75005 Paris, France.
- Université Paris-Saclay, CEA, INRAE, Médicaments et Technologies pour la Santé (DMTS), SPI, MetaboHUB, 91191 Gif-sur-Yvette, France.
ORCID-Profile: Wenqing Xu, Estelle Rathahao-Paris, Sandra Alves
Förderung
- CHIRAMICS project
- MetaboHUB
Zitieren
APA
Xu, W., Rathahao-Paris, E., & Alves, S. (2025). Rapid Enantiomeric Ratio Determination of Multiple Amino Acids Using Ion Mobility-Mass Spectrometry. Molecules, 30(12), 2497. https://doi.org/10.3390/molecules30122497
Vancouver
Xu W, Rathahao-Paris E, Alves S. Rapid Enantiomeric Ratio Determination of Multiple Amino Acids Using Ion Mobility-Mass Spectrometry. Molecules. 2025;30(12):2497. doi:10.3390/molecules30122497
BibTeX
@article{Xu2025,
author = {Xu, Wenqing and Rathahao-Paris, Estelle and Alves, Sandra},
title = {Rapid Enantiomeric Ratio Determination of Multiple Amino Acids Using Ion Mobility-Mass Spectrometry},
journal = {Molecules},
year = {2025},
volume = {30},
number = {12},
pages = {2497},
doi = {10.3390/molecules30122497}
}
EUVIMED