An “On–Off” AIE-Based Lock-and-Key Fluorescent Probe System for Detection of Fentanyl/Norfentanyl
Molecules · 29.04.2025 · 30 (9) · 1985
DOI: 10.3390/molecules30091985 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 29.04.2025. Verfasst von Jing Sun und 8 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Veterinary Public Health Security, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China. Hauptthemen laut MEDLINE: Fentanyl, Fluorescent Dyes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Key Research and Development Program of China, The Talent Development Plan for High-level Public Health Technical Personnel Project, National Key Research and Development Program of China.
Abstract (Originalsprache)
The misuse of fentanyl poses significant social risks, and accurately and swiftly detecting fentanyl in field settings presents a considerable challenge. Herein, we have designed and synthesized a fluorescent probe TP-CF3-COOH, which is composed of carboxyl- and trifluoromethyl-binding center tetraphenyl butadiene. The unique centrosymmetric configuration of the TP-CF3-COOH probe allows for the construction of a fluorescence “on–off” mechanism recognition platform by spatially matching fentanyl and its metabolite norfentanyl. Importantly, this study reveals that the interaction of fentanyl or norfentanyl with TP-CF3-COOH results in spontaneous self-assembly, generating a three-dimensional complex sphere that is smaller than the two-dimensional sheet fluorescence probe. This self-assembly process results in the quenching of fluorescence. Theoretical calculations demonstrate that this process is accompanied by intermolecular through-space charge transfer during self-assembly, leading to a blue shift in emission wavelength. As a result, the TP-CF3-COOH fluorescent probe enables the quantitative detection of fentanyl/norfentanyl within a range of 1 × 10−2–1 × 103 μg/L, with limits of detection of 2 × 10−4 μg/L and 3 × 10−4 μg/L, respectively. This cost-effective, rapid, and sensitive fluorescent probe holds great potential for the onsite screening and detection of fentanyl and its analogues.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Key Laboratory of Veterinary Public Health Security, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China.
- Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Prevention and Control, Beijing 100013, China.
- School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 102488, China.
- College of Science, China Agricultural University, Beijing 100193, China.
ORCID-Profile: Li Zhang
Förderung
- the National Key Research and Development Program of China
- The Talent Development Plan for High-level Public Health Technical Personnel Project
- National Key Research and Development Program of China
- Talent Development Plan for High-level Public Health Technical Personnel Project
Zitieren
APA
Sun, J., Zhi, J., Zhang, L., Qi, Y., Sun, J., Jin, Y., Yin, J., Yao, K., & Shao, B. (2025). An “On–Off” AIE-Based Lock-and-Key Fluorescent Probe System for Detection of Fentanyl/Norfentanyl. Molecules, 30(9), 1985. https://doi.org/10.3390/molecules30091985
Vancouver
Sun J, Zhi J, Zhang L, Qi Y, Sun J, Jin Y, et al. An “On–Off” AIE-Based Lock-and-Key Fluorescent Probe System for Detection of Fentanyl/Norfentanyl. Molecules. 2025;30(9):1985. doi:10.3390/molecules30091985
BibTeX
@article{Sun2025,
author = {Sun, Jing and Zhi, Junge and Zhang, Li and Qi, Yan and Sun, Jiefang and Jin, Yushen and Yin, Jie and Yao, Kai and Shao, Bing},
title = {An “On–Off” AIE-Based Lock-and-Key Fluorescent Probe System for Detection of Fentanyl/Norfentanyl},
journal = {Molecules},
year = {2025},
volume = {30},
number = {9},
pages = {1985},
doi = {10.3390/molecules30091985}
}
EUVIMED