EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electrochemical Degradation of Venlafaxine on Platinum Electrodes: Identification of Transformation Products by LC-MS/MS and In Silico Ecotoxicity Assessment

Angelica R Zizzamia, Veronica Pasquariello, Filomena Lelario iD, Carmen Tesoro iD, Rosanna Ciriello

Molecules · 23.04.2025 · 30 (9) · 1881

DOI: 10.3390/molecules30091881 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 23.04.2025. Verfasst von Angelica R Zizzamia und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Basic and Applied Sciences, University of Basilicata, 85100 Potenza, Italy. Hauptthemen laut MEDLINE: Venlafaxine Hydrochloride, Platinum, Electrochemical Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Antidepressants are emerging contaminants that have raised global concern due to their abuse. Venlafaxine (VFX), a serotonin and norepinephrine reuptake inhibitor, can cause adverse and potentially toxic effects on aquatic organisms. Electrochemical advanced oxidation processes (EAOPs) are gaining attention as promising degradation techniques for a variety of drugs. EAOP methods proposed for VFX degradation mainly utilize boron-doped diamond (BDD) electrodes, characterized by low background current and high oxygen overpotential. However, challenges arise, including delamination from the substrate, difficulties in scaling up, and limited service life. In this study, platinum was employed as an anode for the galvanostatic degradation of VFX, due to its stability and well-established surface cleaning procedure, which ensured high reproducibility. A 0.1 M Na2SO4 solution at pH 9 was used as the supporting electrolyte, and a current density of 25 mA/cm2 was applied. After 7 h, a degradation efficiency of 94% was achieved for a 25 ppm VFX solution. The hydroxyl and sulfate radicals generated in the electrochemical system were the active species responsible for VFX degradation, which followed a first-order kinetic model with a rate constant of 0.0084 min−1. The main degradation intermediates were identified through LC-MS, including two isomers with a nominal m/z of 276 and three isomers with a nominal m/z of 294. The toxicity of the VFX degradation products was assessed by an in silico prediction model. This evaluation confirmed the sustainability of the developed method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Venlafaxine HydrochloridePlatinumElectrochemical TechniquesElectrodesTandem Mass SpectrometryChromatography, LiquidOxidation-ReductionWater Pollutants, ChemicalComputer SimulationLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

LC-MSdegradation intermediateselectrochemical degradationin silico toxicityplatinum platevenlafaxine

Substanzen

Venlafaxine HydrochloridePlatinumWater Pollutants, Chemical

Autor:innen und Institutionen

  • Department of Basic and Applied Sciences, University of Basilicata, 85100 Potenza, Italy.

ORCID-Profile: Filomena Lelario, Carmen Tesoro

Zitieren

APA

Zizzamia, A. R., Pasquariello, V., Lelario, F., Tesoro, C., & Ciriello, R. (2025). Electrochemical Degradation of Venlafaxine on Platinum Electrodes: Identification of Transformation Products by LC-MS/MS and In Silico Ecotoxicity Assessment. Molecules, 30(9), 1881. https://doi.org/10.3390/molecules30091881

Vancouver

Zizzamia AR, Pasquariello V, Lelario F, Tesoro C, Ciriello R. Electrochemical Degradation of Venlafaxine on Platinum Electrodes: Identification of Transformation Products by LC-MS/MS and In Silico Ecotoxicity Assessment. Molecules. 2025;30(9):1881. doi:10.3390/molecules30091881

BibTeX
@article{Zizzamia2025,
  author = {Zizzamia, Angelica R and Pasquariello, Veronica and Lelario, Filomena and Tesoro, Carmen and Ciriello, Rosanna},
  title = {Electrochemical Degradation of Venlafaxine on Platinum Electrodes: Identification of Transformation Products by LC-MS/MS and In Silico Ecotoxicity Assessment},
  journal = {Molecules},
  year = {2025},
  volume = {30},
  number = {9},
  pages = {1881},
  doi = {10.3390/molecules30091881}
}
Kostenlos starten →