Bar Adsorptive Microextraction Approach for Trace Determination of Local Anesthetics in Urine Matrices
Molecules · 27.12.2024 · 30 (1) · 68
DOI: 10.3390/molecules30010068 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 27.12.2024. Verfasst von Joana R P Pereira und 6 weiteren Autor:innen. Beteiligte Einrichtung: Laboratório de Ciências Forenses e Psicológicas Egas Moniz, Molecular Pathology and Forensic Biochemistry Laboratory, Egas Moniz Center for Interdisc…. Hauptthemen laut MEDLINE: Anesthetics, Local, Solid Phase Microextraction. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, FCT/MCTES.
Abstract (Originalsprache)
The present work reports the development, optimization, and validation, of a methodology to determine lidocaine, procaine, tetracaine, and benzocaine in urine matrices. Two extractive preconcentration techniques, solid-phase microextraction (SPME) LC Tips and bar adsorptive microextraction (BAμE), were studied and applied to the four target anesthetics, followed by gas chromatography-mass spectrometry (GC-MS) analysis. Several parameters that could affect microextraction and back-extraction were optimized using two different designs of experiments (Box–Behnken and full-factorial) to maximize extraction efficiency from aqueous media. Under optimized experimental conditions, the BAμE technique showed better performance than SPME LC Tips and was chosen for validation assays and urine sample analysis. In blank urine, the BAµE/GC-MS methodology revealed suitable sensitivity (LOD between 2 and 18 ng/mL), good linearity (r2 ≥ 0.9945) between 0.5 and 30.0 µg/mL and recovery yields of 30.3–97.9%. Good precision (%RSD ≤ 8.8%) and accuracy (bias % between −15.9 and 15.0%) values were achieved. The developed methodology was successfully applied to the target anesthetics analysis of volunteers’ urine matrices and proved to be an environmentally friendly alternative to monitor trace levels of local anesthetics in complex matrices compared to other extraction techniques.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratório de Ciências Forenses e Psicológicas Egas Moniz, Molecular Pathology and Forensic Biochemistry Laboratory, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health and Science, Quinta da…
- Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal.
- Oral Rehabilitation Department, CiiEM, Instituto Universitário Egas Moniz, Quinta da Granja, Monte de Caparica, 2829-511 Caparica, Portugal.
ORCID-Profile: Joana R P Pereira, Nuno R Neng, Paulo Maurício, M Edite Torres, Samir M Ahmad, Alexandre Quintas
Förderung
- Fundação para a Ciência e Tecnologia
- FCT/MCTES
Zitieren
APA
Pereira, J. R. P., Rocha, D. C., Neng, N. R., Maurício, P., Torres, M. E., Ahmad, S. M., & Quintas, A. (2024). Bar Adsorptive Microextraction Approach for Trace Determination of Local Anesthetics in Urine Matrices. Molecules, 30(1), 68. https://doi.org/10.3390/molecules30010068
Vancouver
Pereira JRP, Rocha DC, Neng NR, Maurício P, Torres ME, Ahmad SM, et al. Bar Adsorptive Microextraction Approach for Trace Determination of Local Anesthetics in Urine Matrices. Molecules. 2024;30(1):68. doi:10.3390/molecules30010068
BibTeX
@article{Pereira2024,
author = {Pereira, Joana R P and Rocha, Daniela C and Neng, Nuno R and Maurício, Paulo and Torres, M Edite and Ahmad, Samir M and Quintas, Alexandre},
title = {Bar Adsorptive Microextraction Approach for Trace Determination of Local Anesthetics in Urine Matrices},
journal = {Molecules},
year = {2024},
volume = {30},
number = {1},
pages = {68},
doi = {10.3390/molecules30010068}
}
EUVIMED