EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Green Microfluidic Method for Sustainable and High-Speed Analysis of Basic Amino Acids in Nutritional Supplements

Iva Pukleš iD, Csilla Páger iD, Nikola Sakač, Bojan Šarkanj iD, Dean Marković iD, Marija Kraševac Sakač, Marija Jozanović iD

Molecules · 25.11.2024 · 29 (23) · 5554

DOI: 10.3390/molecules29235554 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 25.11.2024. Verfasst von Iva Pukleš und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8, HR-31000 Osijek, Croatia. Hauptthemen laut MEDLINE: Dietary Supplements. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Croatian Science Foundation, European Structural and Investment Funds grant for the Croatian, European Structural and Investment Funds grant for the Croatian National Scientific Center of Excellence for Personalized Health Care.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Amino acids (AAs) have broad nutritional, therapeutic, and medical significance and thus are one of the most common active ingredients of nutritional supplements. Analytical strategies for determining AAs are high-priced and often limited to methods that require modification of AA polarity or incorporation of an aromatic moiety. The aim of this work was to develop a new method for the determination of L-arginine, L-ornithine, and L-lysine on low-cost microchip electrophoresis instrumentation conjugated with capacitively coupled contactless conductivity detection. A solution consisting of 0.3 M acetic acid and 1 × 10−5 M iminodiacetic acid has been identified as the optimal background electrolyte, ensuring the shortest possible analysis time. The short migration times of amino acids (t ≤ 64 s) and method simplicity resulted in high analysis throughput with high precision and linearity (R2≥ 0.9971). The limit of detection values ranged from 0.15 to 0.19 × 10−6 M. The accuracy of the proposed method was confirmed by recovery measurements. The results were compared with CE-UV-VIS and HPLC-DAD methods and showed good agreement. This work represents the first successful demonstration of the ME-C4D analysis of L-arginine, L-ornithine, and L-lysine in real samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dietary SupplementsAmino Acids, BasicArginineOrnithineGreen Chemistry TechnologyChromatography, High Pressure LiquidElectrophoresis, MicrochipMicrofluidicsLimit of Detection

Stichwörter der Autor:innen

L-arginineL-lysineL-ornithineamino acidscapacitively coupled contactless conductivity detectionmicrochip electrophoresisnutritional supplementssustainable

Substanzen

Amino Acids, BasicArginineOrnithine

Autor:innen und Institutionen

  • Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8, HR-31000 Osijek, Croatia.
  • Doctoral School of Chemistry, University of Pécs, Ifjúság útja, 7624 Pécs, Hungary.
  • Department of Analytical and Environmental Chemistry, Faculty of Sciences, University of Pécs, Ifjúság útja, 7624 Pécs, Hungary.
  • Institute of Bioanalysis, Medical School, Szentágothai Research Center, University of Pécs, 7624 Pécs, Hungary.
  • Faculty of Geotechnical Engineering, University of Zagreb, Hallerova 7, HR-42000 Varaždin, Croatia.
  • Department of Food Technology, University North, Trg dr. Žarka Dolinara 1, HR-48000 Koprivnica, Croatia.

ORCID-Profile: Iva Pukleš, Csilla Páger, Bojan Šarkanj, Dean Marković, Marija Jozanović

Förderung

  • Croatian Science Foundation
  • European Structural and Investment Funds grant for the Croatian
  • European Structural and Investment Funds grant for the Croatian National Scientific Center of Excellence for Personalized Health Care

Zitieren

APA

Pukleš, I., Páger, C., Sakač, N., Šarkanj, B., Marković, D., Sakač, M. K., & Jozanović, M. (2024). Green Microfluidic Method for Sustainable and High-Speed Analysis of Basic Amino Acids in Nutritional Supplements. Molecules, 29(23), 5554. https://doi.org/10.3390/molecules29235554

Vancouver

Pukleš I, Páger C, Sakač N, Šarkanj B, Marković D, Sakač MK, et al. Green Microfluidic Method for Sustainable and High-Speed Analysis of Basic Amino Acids in Nutritional Supplements. Molecules. 2024;29(23):5554. doi:10.3390/molecules29235554

BibTeX
@article{Pukle2024,
  author = {Pukleš, Iva and Páger, Csilla and Sakač, Nikola and Šarkanj, Bojan and Marković, Dean and Sakač, Marija Kraševac and Jozanović, Marija},
  title = {Green Microfluidic Method for Sustainable and High-Speed Analysis of Basic Amino Acids in Nutritional Supplements},
  journal = {Molecules},
  year = {2024},
  volume = {29},
  number = {23},
  pages = {5554},
  doi = {10.3390/molecules29235554}
}
Kostenlos starten →