Au Nanoshell-Based Lateral Flow Immunoassay for Colorimetric and Photothermal Dual-Mode Detection of Interleukin-6
Molecules · 2024
DOI: 10.3390/molecules29153683 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, 2024. Verfasst von Congying Wen und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China. Hauptthemen laut MEDLINE: Interleukin-6, Gold, Colorimetry. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Scientific Foundation of Shandong, National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Interleukin-6 (IL-6) detection and monitoring are of great significance for evaluating the progression of many diseases and their therapeutic efficacy. Lateral flow immunoassay (LFIA) is one of the most promising point-of-care testing (POCT) methods, yet suffers from low sensitivity and poor quantitative ability, which greatly limits its application in IL-6 detection. Hence, in this work, we integrated Aushell nanoparticles (NPs) as new LFIA reporters and achieved the colorimetric and photothermal dual-mode detection of IL-6. Aushell NPs were conveniently prepared using a galvanic exchange process. By controlling the shell thickness, their localized surface plasmon resonance (LSPR) peak was easily tuned to near-infrared (NIR) range, which matched well with the NIR irradiation light. Thus, the Aushell NPs were endowed with good photothermal effect. Aushell NPs were then modified with IL-6 detection antibody to construct Aushell probes. In the LFIA detection, the Aushell probes were combined with IL-6, which were further captured by the capture IL-6 antibody on the test line of the strip, forming a colored band. By observation with naked eyes, the colorimetric qualitative detection of IL-6 was achieved with limit of 5 ng/mL. By measuring the temperature rise of the test line with a portable infrared thermal camera, the photothermal quantitative detection of IL-6 was performed from 1~1000 ng/mL. The photothermal detection limit reached 0.3 ng/mL, which was reduced by nearly 20 times compared with naked-eye detection. Therefore, this Aushell-based LFIA efficiently improved the sensitivity and quantitative ability of commercial colloidal gold LFIA. Furthermore, this method showed good specificity, and kept the advantages of convenience, speed, cost-effectiveness, and portability. Therefore, this Aushell-based LFIA exhibits practical application potential in IL-6 POCT detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry and Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China.
- Qingdao Academy of Agricultural Sciences, Qingdao 266100, China.
ORCID-Profile: Congying Wen
Förderung
- Natural Scientific Foundation of Shandong
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
- College Student Innovation Project
Zitieren
APA
Wen, C., Dou, Y., Liu, Y., Jiang, X., Tu, X., & Zhang, R. (2024). Au Nanoshell-Based Lateral Flow Immunoassay for Colorimetric and Photothermal Dual-Mode Detection of Interleukin-6. Molecules. https://doi.org/10.3390/molecules29153683
Vancouver
Wen C, Dou Y, Liu Y, Jiang X, Tu X, Zhang R. Au Nanoshell-Based Lateral Flow Immunoassay for Colorimetric and Photothermal Dual-Mode Detection of Interleukin-6. Molecules. 2024. doi:10.3390/molecules29153683
BibTeX
@article{Wen2024,
author = {Wen, Congying and Dou, Yue and Liu, Yao and Jiang, Xuan and Tu, Xiaomei and Zhang, Ruiqiao},
title = {Au Nanoshell-Based Lateral Flow Immunoassay for Colorimetric and Photothermal Dual-Mode Detection of Interleukin-6},
journal = {Molecules},
year = {2024},
doi = {10.3390/molecules29153683}
}
EUVIMED