EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Measurement Uncertainty and Risk of False Compliance Assessment Applied to Carbon Isotopic Analyses in Natural Gas Exploratory Evaluation

Fabiano Galdino Leal, Alexandre de Andrade Ferreira, Gabriel Moraes Silva iD, Tulio Alves Freire, Marcelo Ribeiro Costa, Erica Tavares de Morais, Jarbas Vicente Poley Guzzo, Elcio Cruz de Oliveira iD

Molecules · 27.06.2024 · 29 (13) · 3065

DOI: 10.3390/molecules29133065 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 27.06.2024. Verfasst von Fabiano Galdino Leal und 7 weiteren Autor:innen. Beteiligte Einrichtung: Research Center, Petrobras S.A., Rio de Janeiro 21941-915, Brazil. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Council for Scientific and Technological Development, Coordenação de Aperfeicoamento de Pessoal de Nível Superior, Brazilian agency CNPq.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The concept of uncertainty in an isotopic analysis is not uniform in the scientific community worldwide and can compromise the risk of false compliance assessment applied to carbon isotopic analyses in natural gas exploratory evaluation. In this work, we demonstrated a way to calculate one of the main sources of this uncertainty, which is underestimated in most studies focusing on gas analysis: the δ13C calculation itself is primarily based on the raw analytical data. The carbon isotopic composition of methane, ethane, propane, and CO2 was measured. After a detailed mathematical treatment, the corresponding expanded uncertainties for each analyte were calculated. Next, for the systematic isotopic characterization of the two gas standards, we calculated the standard uncertainty, intermediary precision, combined standard uncertainty, and finally, the expanded uncertainty for methane, ethane, propane, and CO2. We have found an expanded uncertainty value of 1.8‰ for all compounds, except for propane, where a value of 1.6‰ was obtained. The expanded uncertainty values calculated with the approach shown in this study reveal that the error arising from the application of delta calculation algorithms cannot be neglected, and the obtained values are higher than 0.5‰, usually considered as the accepted uncertainty associated with the GC-IRMS analyses. Finally, based on the use of uncertainty information to evaluate the risk of false compliance, the lower and upper acceptance limits for the carbon isotopic analysis of methane in natural gas are calculated, considering the exploratory limits between −55‰ and −50‰: (i) for the underestimated current uncertainty of 0.5‰, the lower and upper acceptance limits, respectively, are −54.6‰ and −50.4‰; and (ii) for the proposed realistic uncertainty of 1.8‰, the lower and upper acceptance limits would be more restrictive; i.e., −53.5‰ and −51.5‰, respectively.

Schlagwörter

Stichwörter der Autor:innen

biogenic isotopic compositiongas geochemistrymeasurement uncertaintynatural gas exploratory evaluationstable isotope analysis

Autor:innen und Institutionen

  • Research Center, Petrobras S.A., Rio de Janeiro 21941-915, Brazil.
  • Center for Energy Resources Engineering, Department of Chemical and Biochemical Engineering, Technical University of Denmark, 2800 Kongens Lyngby, Denmark.
  • Postgraduate Programme in Metrology, Pontifical Catholic University of Rio de Janeiro, Rio de Janeiro 22451-900, Brazil.
  • Land Transportation and Storage, Measurement and Product Inventory Management, Logistics, Petrobras S.A., Rio de Janeiro 20231-030, Brazil.

ORCID-Profile: Gabriel Moraes Silva, Elcio Cruz de Oliveira

Förderung

  • National Council for Scientific and Technological Development
  • Coordenação de Aperfeicoamento de Pessoal de Nível Superior
  • Brazilian agency CNPq
  • Coordination for the Improvement of Higher Education Personnel—Brazil (CAPES)

Zitieren

APA

Leal, F. G., de Andrade Ferreira, A., Silva, G. M., Freire, T. A., Costa, M. R., de Morais, E. T., Guzzo, J. V. P., & de Oliveira, E. C. (2024). Measurement Uncertainty and Risk of False Compliance Assessment Applied to Carbon Isotopic Analyses in Natural Gas Exploratory Evaluation. Molecules, 29(13), 3065. https://doi.org/10.3390/molecules29133065

Vancouver

Leal FG, de Andrade Ferreira A, Silva GM, Freire TA, Costa MR, de Morais ET, et al. Measurement Uncertainty and Risk of False Compliance Assessment Applied to Carbon Isotopic Analyses in Natural Gas Exploratory Evaluation. Molecules. 2024;29(13):3065. doi:10.3390/molecules29133065

BibTeX
@article{Leal2024,
  author = {Leal, Fabiano Galdino and de Andrade Ferreira, Alexandre and Silva, Gabriel Moraes and Freire, Tulio Alves and Costa, Marcelo Ribeiro and de Morais, Erica Tavares and Guzzo, Jarbas Vicente Poley and de Oliveira, Elcio Cruz},
  title = {Measurement Uncertainty and Risk of False Compliance Assessment Applied to Carbon Isotopic Analyses in Natural Gas Exploratory Evaluation},
  journal = {Molecules},
  year = {2024},
  volume = {29},
  number = {13},
  pages = {3065},
  doi = {10.3390/molecules29133065}
}
Kostenlos starten →