Non-Enzymatic Glucose Sensors Composed of Polyaniline Nanofibers with High Electrochemical Performance
Molecules · 2024
DOI: 10.3390/molecules29112439 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, 2024. Verfasst von Nebras Sobahi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical & Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia. Hauptthemen laut MEDLINE: Aniline Compounds, Nanofibers, Electrochemical Techniques, Glucose. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Andulaziz University, Institutional Fund Projects, Ministry of Education and King Abdulaziz University, Jeddah, Saudi Arabia.
Abstract (Originalsprache)
The measurement of glucose concentration is a fundamental daily care for diabetes patients, and therefore, its detection with accuracy is of prime importance in the field of health care. In this study, the fabrication of an electrochemical sensor for glucose sensing was successfully designed. The electrode material was fabricated using polyaniline and systematically characterized using scanning electron microscopy, high-resolution transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and UV-visible spectroscopy. The polyaniline nanofiber-modified electrode showed excellent detection ability for glucose with a linear range of 10 μM to 1 mM and a detection limit of 10.6 μM. The stability of the same electrode was tested for 7 days. The electrode shows high sensitivity for glucose detection in the presence of interferences. The polyaniline-modified electrode does not affect the presence of interferences and has a low detection limit. It is also cost-effective and does not require complex sample preparation steps. This makes it a potential tool for glucose detection in pharmacy and medical diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electrical & Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
- Department of Chemical Engineering, College of Engineering, Jazan University, Jazan 45142, Saudi Arabia.
- Department of Chemical Engineering Technology, College of Applied Industrial Technology, Jazan University, Jazan 45142, Saudi Arabia.
- School of Chemical Engineering, Yeungnam University, Gyeongsan-si 38541, Gyeongbuk-do, Republic of Korea.
- Center of Excellence in Intelligent Engineering Systems (CEIES), King Abdulaziz University, Jeddah 21589, Saudi Arabia.
ORCID-Profile: Nebras Sobahi, Md Mottahir Alam, Mohd Imran, Mohammad Ehtisham Khan, Akbar Mohammad, Taeho Yoon, Ibrahim M Mehedi, Mohammed J Abdulaal, Ahmad A Jiman
Förderung
- King Andulaziz University
- Institutional Fund Projects
- Ministry of Education and King Abdulaziz University, Jeddah, Saudi Arabia
Zitieren
APA
Sobahi, N., Alam, M. M., Imran, M., Khan, M. E., Mohammad, A., Yoon, T., Mehedi, I. M., Hussain, M. A., Abdulaal, M. J., & Jiman, A. A. (2024). Non-Enzymatic Glucose Sensors Composed of Polyaniline Nanofibers with High Electrochemical Performance. Molecules. https://doi.org/10.3390/molecules29112439
Vancouver
Sobahi N, Alam MM, Imran M, Khan ME, Mohammad A, Yoon T, et al. Non-Enzymatic Glucose Sensors Composed of Polyaniline Nanofibers with High Electrochemical Performance. Molecules. 2024. doi:10.3390/molecules29112439
BibTeX
@article{Sobahi2024,
author = {Sobahi, Nebras and Alam, Md Mottahir and Imran, Mohd and Khan, Mohammad Ehtisham and Mohammad, Akbar and Yoon, Taeho and Mehedi, Ibrahim M and Hussain, Mohammad A and Abdulaal, Mohammed J and Jiman, Ahmad A},
title = {Non-Enzymatic Glucose Sensors Composed of Polyaniline Nanofibers with High Electrochemical Performance},
journal = {Molecules},
year = {2024},
doi = {10.3390/molecules29112439}
}
EUVIMED