EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wastewater Characterization: Chemical Oxygen Demand or Total Organic Carbon Content Measurement?

László Wojnárovits, Renáta Homlok, Krisztina Kovács, Anna Tegze, Ezsébet Takács

Molecules · 14.01.2024 · 29 (2) · 405

DOI: 10.3390/molecules29020405 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 14.01.2024. Verfasst von László Wojnárovits und 4 weiteren Autor:innen. Beteiligte Einrichtung: HUN-REN Centre for Energy Research, Konkoly-Thege M. út 29-33, 1121 Budapest, Hungary. Die Arbeit wurde bisher 52-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: International Atomic Energy Agency, National Research, Development and Innovation Office of Hungary.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The long time (2 h) required for measurement, expensive chemicals (Ag2SO4), and toxic reagents (K2Cr2O7, HgSO4) limit the application of the standard method for measuring the oxygen equivalent of organic content in wastewater (chemical oxygen demand, COD). In recent years, the COD has increasingly been replaced by the total organic carbon (TOC) parameter. Since the limit values of the pollution levels are usually given in terms of the COD, efforts are being made to find the correlation between these parameters. Several papers have published correlation analyses of COD and TOC for industrial and municipal wastewater, but the relationship has not been discussed for individual chemicals. Here, this relationship was investigated using 70 contaminants (laboratory chemicals, pharmaceuticals, and pesticides). The calculated COD values, in most cases, agreed, within ~10%, with the experimental ones; for tetracyclines and some chloroaromatic molecules, the measured values were 20–50% lower than the calculated values. The COD/TOC ratios were between 2 and 3: for macrolides, they were ~3; for fluoroquinolones and tetracyclines, they were ~2. The molecular structure dependence of the ratio necessitates the establishing of the correlation on an individual basis. In advanced oxidation processes (AOPs), the ratio changes during degradation, limiting the application of TOC instead of COD.

Schlagwörter

Stichwörter der Autor:innen

advanced oxidation processeschemical oxygen demandgamma radiolysispharmaceuticalstotal organic carbon

Autor:innen und Institutionen

  • HUN-REN Centre for Energy Research, Konkoly-Thege M. út 29-33, 1121 Budapest, Hungary.

Förderung

  • International Atomic Energy Agency
  • National Research, Development and Innovation Office of Hungary

Zitieren

APA

Wojnárovits, L., Homlok, R., Kovács, K., Tegze, A., & Takács, E. (2024). Wastewater Characterization: Chemical Oxygen Demand or Total Organic Carbon Content Measurement?. Molecules, 29(2), 405. https://doi.org/10.3390/molecules29020405

Vancouver

Wojnárovits L, Homlok R, Kovács K, Tegze A, Takács E. Wastewater Characterization: Chemical Oxygen Demand or Total Organic Carbon Content Measurement?. Molecules. 2024;29(2):405. doi:10.3390/molecules29020405

BibTeX
@article{Wojnrovits2024,
  author = {Wojnárovits, László and Homlok, Renáta and Kovács, Krisztina and Tegze, Anna and Takács, Ezsébet},
  title = {Wastewater Characterization: Chemical Oxygen Demand or Total Organic Carbon Content Measurement?},
  journal = {Molecules},
  year = {2024},
  volume = {29},
  number = {2},
  pages = {405},
  doi = {10.3390/molecules29020405}
}
Kostenlos starten →