ALP-Based Biosensors Employing Electrodes Modified with Carbon Nanomaterials for Pesticides Detection
Molecules · 2023
DOI: 10.3390/molecules28041532 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, 2023. Verfasst von Stefano Gianvittorio und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Industrial Chemistry "Toso Montanari", Alma Mater Studiorum-University of Bologna, Viale del Risorgimento 4, 40136 Bologna, Italy. Hauptthemen laut MEDLINE: Biosensing Techniques, Nanotubes, Carbon, Pesticides. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Universities and Research, Bologna University.
Abstract (Originalsprache)
Due to the growing presence of pesticides in the environment and in food, the concern of their impact on human health is increasing. Therefore, the development of fast and reliable detection methods is needed. Enzymatic inhibition-based biosensors represent a good alternative for replacing the more complicated and time-consuming traditional methods (chromatography, spectrophotometry, etc.). This paper describes the development of an electrochemical biosensor exploiting alkaline phosphatase as the biological recognition element and a chemically modified glassy carbon electrode as the transducer. The biosensor was prepared modifying the GCE surface by a mixture of Multi-Walled-Carbon-Nanotubes (MWCNTs) and Electrochemically-Reduced-Graphene-Oxide (ERGO) followed by the immobilization of the enzyme by cross-linking with bovine serum albumin and glutaraldehyde. The inhibition of the biosensor response caused by pesticides was established using 2-phospho-L-ascorbic acid as the enzymatic substrate, whose dephosphorylation reaction produces ascorbic acid (AA). The MWCNTs/ERGO mixture shows a synergic effect in terms of increased sensitivity and decreased overpotential for AA oxidation. The response of the biosensor to the herbicide 2,4-dichloro-phenoxy-acetic-acid was evaluated and resulted in the concentration range 0.04–24 nM, with a limit of the detection of 16 pM. The determination of other pesticides was also achieved. The re-usability of the electrode was demonstrated by performing a washing procedure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Industrial Chemistry "Toso Montanari", Alma Mater Studiorum-University of Bologna, Viale del Risorgimento 4, 40136 Bologna, Italy.
ORCID-Profile: Stefano Gianvittorio, Isacco Gualandi, Domenica Tonelli
Förderung
- Ministry of Education, Universities and Research
- Bologna University
Zitieren
APA
Gianvittorio, S., Gualandi, I., & Tonelli, D. (2023). ALP-Based Biosensors Employing Electrodes Modified with Carbon Nanomaterials for Pesticides Detection. Molecules. https://doi.org/10.3390/molecules28041532
Vancouver
Gianvittorio S, Gualandi I, Tonelli D. ALP-Based Biosensors Employing Electrodes Modified with Carbon Nanomaterials for Pesticides Detection. Molecules. 2023. doi:10.3390/molecules28041532
BibTeX
@article{Gianvittorio2023,
author = {Gianvittorio, Stefano and Gualandi, Isacco and Tonelli, Domenica},
title = {ALP-Based Biosensors Employing Electrodes Modified with Carbon Nanomaterials for Pesticides Detection},
journal = {Molecules},
year = {2023},
doi = {10.3390/molecules28041532}
}
EUVIMED