EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reducing Bypass in Hydrocyclones: Part I—Preliminary Testing and Assessments

Allan Suhett Reis, Homero Delboni

Minerals · 31.03.2026 · 16 (4) · 375

DOI: 10.3390/min16040375 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Minerals, online erschienen am 31.03.2026. Verfasst von Allan Suhett Reis und 1 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Norsk Hydro.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hydrocyclones are widely applied devices in mineral processing due to their simple design, high capacity and low operational costs. Some of the main applications are classification in closed grinding circuits and desliming, as well as dewatering. However, hydrocyclones have an inherent inefficiency known as the fine particles bypass to the underflow stream, often associated with entrainment by water flow. Several approaches have been proposed to mitigate fine particle bypass, such as optimizing hydrocyclone design, adjusting apex and vortex finder diameters, water injection systems and improved inlet design. The objective of the present work was to assess hydrocyclone performance on different apex and vortex diameter combinations, seeking the reduction in fine particles bypass to underflow on the Paragominas bauxite processing industrial desliming circuit. Two different bauxite samples were used in a hydrocyclone classification test work, carried out on a specially built pilot plant. Six different combinations of apex and vortex were evaluated in a 254 mm diameter hydrocyclone, covering a range of apex-to-vortex diameters from 0.38 to 0.57. The results indicate operating conditions that significantly reduce fine particles bypass to underflow, increasing classification efficiency with minor effects in overflow selected size distribution parameter—d95. Accordingly, smaller apex-to-vortex ratios result in overall better performances, reducing fine particles bypass to underflow from 33% to 7%, as well as reducing the partition curve slope from 0.52 to 0.21 for one of the tested samples. Significant benefits are also obtained in terms of reducing the contents of reactive silica in the underflow of the optimized desliming hydrocyclone.

Förderung

  • Norsk Hydro

Zitieren

APA

Reis, A. S., & Delboni, H. (2026). Reducing Bypass in Hydrocyclones: Part I—Preliminary Testing and Assessments. Minerals, 16(4), 375. https://doi.org/10.3390/min16040375

Vancouver

Reis AS, Delboni H. Reducing Bypass in Hydrocyclones: Part I—Preliminary Testing and Assessments. Minerals. 2026;16(4):375. doi:10.3390/min16040375

BibTeX
@article{Reis2026,
  author = {Reis, Allan Suhett and Delboni, Homero},
  title = {Reducing Bypass in Hydrocyclones: Part I—Preliminary Testing and Assessments},
  journal = {Minerals},
  year = {2026},
  volume = {16},
  number = {4},
  pages = {375},
  doi = {10.3390/min16040375}
}
Kostenlos starten →