Fast Forward: Optimized Sample Preparation and Fluorescent Staining for Microplastic Detection
Microplastics · 22.10.2023 · 2 (4) · 334-349
DOI: 10.3390/microplastics2040026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microplastics, online erschienen am 22.10.2023. Verfasst von Michael Toni Sturm und 5 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union’s HORIZON EUROPE innovation program, the Veolia Foundation (GERMANY)|Project konti|detect and by Vector Stiftung/GERMANY.
Abstract (Originalsprache)
The fast, affordable, and standardized detection of microplastics (MP) remains one of the biggest challenges in MP research. Comparable data are essential for appropriate risk assessments and the implementation of laws and limit values. The fluorescent staining of MP in environmental samples is a possible solution to this problem. This study investigates the optimization of a sample preparation process (hydrogen peroxide digestion) and the staining process (temperature, concentration, time, surfactants as staining aids) for using a specifically developed fluorescent dye for MP detection. The optimization is performed by comparing the sample preparation process and staining of MP from different polymers and natural particles. Further, the suitability of the optimized process for the detection of fluoropolymers and tire abrasion was tested. The results show that the optimized method (increased temperature and optimized stain concentration) can detect microplastics reliably with a total sample preparation and measurement time of 2.5–3 h per sample, reaching recovery rates of 93.3% (polypropylene) to 101.7% (polyester). Moreover, two of the three tested fluoropolymers could be detected reliably. Tire abrasion could not be detected with the here presented method, as the black color leads to strong quenching. A long-term study measuring the MP pollution in the effluent of a municipal wastewater treatment plant compared the optimized and original processes and confirmed the stability of the improved method for routine measurements and contamination control.
Förderung
- European Union’s HORIZON EUROPE innovation program
- the Veolia Foundation (GERMANY)|Project konti|detect and by Vector Stiftung/GERMANY
Zitieren
APA
Sturm, M. T., Myers, E., Korzin, A., Polierer, S., Schober, D., & Schuhen, K. (2023). Fast Forward: Optimized Sample Preparation and Fluorescent Staining for Microplastic Detection. Microplastics, 2(4), 334-349. https://doi.org/10.3390/microplastics2040026
Vancouver
Sturm MT, Myers E, Korzin A, Polierer S, Schober D, Schuhen K. Fast Forward: Optimized Sample Preparation and Fluorescent Staining for Microplastic Detection. Microplastics. 2023;2(4):334-349. doi:10.3390/microplastics2040026
BibTeX
@article{Sturm2023,
author = {Sturm, Michael Toni and Myers, Erika and Korzin, Anika and Polierer, Sabrina and Schober, Dennis and Schuhen, Katrin},
title = {Fast Forward: Optimized Sample Preparation and Fluorescent Staining for Microplastic Detection},
journal = {Microplastics},
year = {2023},
volume = {2},
number = {4},
pages = {334--349},
doi = {10.3390/microplastics2040026}
}
EUVIMED