EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative Microbial Risk Assessment of Airborne Viruses and Semi-Quantitative Bacterial Risk Scoring in Occupied European Indoor Environments: A Multi-Country Study

Ioanna P. Chatziprodromidou, Rafail Fokas, Angeliki Chatziantoniou, Kalypso Angeliki Koukouvini, Stylianos Karatzas, Apostolos Vantarakis

Microorganisms · 21.11.2026 · 14 (12) · 2711

DOI: 10.3390/microorganisms14122711 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microorganisms, online erschienen am 21.11.2026. Verfasst von Ioanna P. Chatziprodromidou und 5 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union’s Horizon Europe research and innovation programme.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative microbial risk assessment (QMRA) is well established for waterborne and foodborne hazards but rarely applied to airborne pathogens in real occupied buildings, where viral loads are low, intermittent, and left-censored and where bacterial monitoring yields only presence/absence data. We applied a dual bioaerosol framework—probabilistic single-hit dose–response modelling for respiratory viruses and a transparent semi-quantitative scoring model for bacteria—across twenty-two micro-environments in six European countries. Air was sampled with a Sartorius MD8 Airport sampler and gelatin membrane filters on one to four days per phase, and SARS-CoV-2, adenovirus, influenza A, RSV, and rhinovirus were quantified by RT-qPCR, with influenza B assayed but never detected (method limits of detection 437–1860 copies m−3). Exposure was expressed in genome copies, the unit measured, and each dose–response parameter was re-expressed per genome copy, so that the conversion between genome copies and infectious units is carried explicitly by the parameter and propagated as a distribution. Airborne material was subject to first-order inactivation at a rate determined by the measured temperature and relative humidity, which were resampled in pairs from the room’s own sensor record where one covered the sampling days (100,000 Monte Carlo iterations). In the twelve micro-environments with a usable environmental record, the resulting upper-bound probability of infection per occupant per day—for one occupant present through one occupied day on which the agent was detected, infection rather than illness being the endpoint of every parameter used—ranged from 9.0 × 10−7 for influenza A to 0.9998 for SARS-CoV-2 and 0.97 for adenovirus in the most contaminated rooms. These bounds approach their upper limit of 1 and, therefore, stop distinguishing between rooms, and we report them as a measurement of the exposure metric rather than as a forecast: at concentrations reaching 8.4 × 106 genome copies m−3, a genome-copy dose exceeds the published per-infection dose by one to three orders of magnitude, so absolute risk cannot be recovered without knowing the infectious fraction, which RT-qPCR does not measure. Concentrations of a given agent spanned a median factor of five, and up to 283-fold, between the lowest and highest positive sample of a room–phase series, and up to 471-fold between two sampled days anywhere in the network. In a random-effects decomposition of log10 concentration the within-series standard deviation exceeds the between-series one for both agents modelled on repeated samples (0.58 against 0.37 for SARS-CoV-2, 0.49 against 0.22 for adenovirus), so that most of the variation is between days within a room rather than between rooms and a single sampling event characterises neither. That comparison, like the comparison between phases, is made on measured concentrations and is, therefore, unaffected by the unknown scaling. Measured airborne viral concentrations did not fall systematically after the installation of portable air cleaners, and changed in the same direction in rooms that received no device, so no effect can be attributed to the intervention in this design. Swab-derived bacterial scores fell in four of the six micro-environments with paired data, by 32% to 54%, and the air samples yielded more bacterial species than occupant swabs on three of the six occasions on which the two matrices can be compared, substantially so on two of them. For three of the four agents modelled, the dominant uncertainty is the number of genome copies per infectious unit, to which the inhaled dose is proportional and the estimates are proportional until the bound approaches one; for SARS-CoV-2 it is the published range of the genome-copy dose–response parameter, which spans a factor of fifteen. The absolute values are, therefore, upper bounds for SARS-CoV-2, adenovirus, and rhinovirus, while the influenza A values rest on a parameter fitted to attenuated strains and understate the risk from wild-type virus. The conclusions rest on the relative comparisons.

Förderung

  • European Union’s Horizon Europe research and innovation programme

Zitieren

APA

Chatziprodromidou, I. P., Fokas, R., Chatziantoniou, A., Koukouvini, K. A., Karatzas, S., & Vantarakis, A. (2026). Quantitative Microbial Risk Assessment of Airborne Viruses and Semi-Quantitative Bacterial Risk Scoring in Occupied European Indoor Environments: A Multi-Country Study. Microorganisms, 14(12), 2711. https://doi.org/10.3390/microorganisms14122711

Vancouver

Chatziprodromidou IP, Fokas R, Chatziantoniou A, Koukouvini KA, Karatzas S, Vantarakis A. Quantitative Microbial Risk Assessment of Airborne Viruses and Semi-Quantitative Bacterial Risk Scoring in Occupied European Indoor Environments: A Multi-Country Study. Microorganisms. 2026;14(12):2711. doi:10.3390/microorganisms14122711

BibTeX
@article{Chatziprodromidou2026,
  author = {Chatziprodromidou, Ioanna P. and Fokas, Rafail and Chatziantoniou, Angeliki and Koukouvini, Kalypso Angeliki and Karatzas, Stylianos and Vantarakis, Apostolos},
  title = {Quantitative Microbial Risk Assessment of Airborne Viruses and Semi-Quantitative Bacterial Risk Scoring in Occupied European Indoor Environments: A Multi-Country Study},
  journal = {Microorganisms},
  year = {2026},
  volume = {14},
  number = {12},
  pages = {2711},
  doi = {10.3390/microorganisms14122711}
}
Kostenlos starten →