EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Divergent Bacterial Community Structure and Discordance Between Gene Detection and Culture for Legionella Across Four Full-Scale Drinking Water Treatment Plants

Jae Hong Jeong, Min Young Kim, Min-jeong Kim, Jiwon Park, Hyoseong Jeong, Heuidae Lee, Sangjun Park, Gyu-Cheol Lee, Jong-Chan Chae

Microorganisms · 17.11.2026 · 14 (11) · 2666

DOI: 10.3390/microorganisms14112666 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microorganisms, online erschienen am 17.11.2026. Verfasst von Jae Hong Jeong und 8 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: K-water, Jeonbuk National University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Drinking water treatment strongly reshapes source water bacterial communities, yet what determines the community persisting to the tap remains unresolved. We surveyed four full-scale Korean drinking water treatment plants differing in source water (river or lake) and treatment level (conventional or advanced). Seventy-eight samples spanning raw water (RW) to tap water (TP), collected on three occasions in 2025, were analysed by 16S rRNA metabarcoding together with cellular ATP (cATP). Observed amplicon sequence variants declined from 1914 (RW) to 381 in treated water (TW) and 283 in tap water (TP). Shannon diversity differed significantly among these sampling points (Friedman test, χ2(2) = 18.67, p < 0.001). Community structure also differed among sampling points (PERMANOVA, R2 = 0.175, p = 0.001), and between-plant Bray–Curtis dissimilarity increased from 0.768 (RW) to 0.876 (TW), indicating divergence rather than convergence. Residual chlorine was the only variable with significant marginal effects in the common-point and multiple plant-level dbRDA models. Phreatobacter increased at every plant and round, reaching 34.3% (TP), although relative abundance combined with cATP remained close to RW levels. Legionella and Mycobacterium sequences persisted in TW and TP, yet all 36 samples examined by Legionella culture were negative, showing that gene detection alone cannot establish viability.

Förderung

  • K-water
  • Jeonbuk National University

Zitieren

APA

Jeong, J. H., Kim, M. Y., Kim, M., Park, J., Jeong, H., Lee, H., Park, S., Lee, G., & Chae, J. (2026). Divergent Bacterial Community Structure and Discordance Between Gene Detection and Culture for Legionella Across Four Full-Scale Drinking Water Treatment Plants. Microorganisms, 14(11), 2666. https://doi.org/10.3390/microorganisms14112666

Vancouver

Jeong JH, Kim MY, Kim M, Park J, Jeong H, Lee H, et al. Divergent Bacterial Community Structure and Discordance Between Gene Detection and Culture for Legionella Across Four Full-Scale Drinking Water Treatment Plants. Microorganisms. 2026;14(11):2666. doi:10.3390/microorganisms14112666

BibTeX
@article{Jeong2026,
  author = {Jeong, Jae Hong and Kim, Min Young and Kim, Min-jeong and Park, Jiwon and Jeong, Hyoseong and Lee, Heuidae and Park, Sangjun and Lee, Gyu-Cheol and Chae, Jong-Chan},
  title = {Divergent Bacterial Community Structure and Discordance Between Gene Detection and Culture for Legionella Across Four Full-Scale Drinking Water Treatment Plants},
  journal = {Microorganisms},
  year = {2026},
  volume = {14},
  number = {11},
  pages = {2666},
  doi = {10.3390/microorganisms14112666}
}
Kostenlos starten →