Copy Number Studies in Noisy Samples
Microarrays · 2013
DOI: 10.3390/microarrays2040284 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microarrays, 2013. Verfasst von Philip Ginsbach und 4 weiteren Autor:innen. Beteiligte Einrichtung: Neurology Department, University of Heidelberg, INF 400, Heidelberg D69120, Germany. Philip.Ginsbach@t-online.de. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
System noise was analyzed in 77 Affymetrix 6.0 samples from a previous clinical study of copy number variation (CNV). Twenty-three samples were classified as eligible for CNV detection, 29 samples as ineligible and 25 were classified as being of intermediate quality. New software (“noise-free-cnv”) was developed to visualize the data and reduce system noise. Fresh DNA preparations were more likely to yield eligible samples (p < 0.001). Eligible samples had higher rates of successfully genotyped SNPs (p < 0.001) and lower variance of signal intensities (p < 0.001), yielded fewer CNV findings after Birdview analysis (p < 0.001), and showed a tendency to yield fewer PennCNV calls (p = 0.053). The noise-free-cnv software visualized trend patterns of noise in the signal intensities across the ordered SNPs, including a wave pattern of noise, being co-linear with the banding pattern of metaphase chromosomes, as well as system deviations of individual probe sets (per-SNP noise). Wave noise and per-SNP noise occurred independently and could be separately removed from the samples. We recommend a two-step procedure of CNV validation, including noise reduction and visual inspection of all CNV calls, prior to molecular validation of a selected number of putative CNVs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neurology Department, University of Heidelberg, INF 400, Heidelberg D69120, Germany. Philip.Ginsbach@t-online.de.
- Division of Molecular Genetic Epidemiology, German Cancer Research Center, INF 280, Heidelberg D69120, Germany. c.bowang@dkfz-heidelberg.de.
- Neurology Department, University of Heidelberg, INF 400, Heidelberg D69120, Germany. jiangyanxiang@googlemail.com.
- Stroke Unit and Department of Neurology, University Hospital Basel, Petersgraben 4, Basel CH4031, Switzerland. Stefan.Engelter@usb.ch.
- Neurology Department, University of Heidelberg, INF 400, Heidelberg D69120, Germany. Caspar.Grond-Ginsbach@med.uni-heidelberg.de.
Zitieren
APA
Ginsbach, P., Chen, B., Jiang, Y., Engelter, S. T., & Grond-Ginsbach, C. (2013). Copy Number Studies in Noisy Samples. Microarrays. https://doi.org/10.3390/microarrays2040284
Vancouver
Ginsbach P, Chen B, Jiang Y, Engelter ST, Grond-Ginsbach C. Copy Number Studies in Noisy Samples. Microarrays. 2013. doi:10.3390/microarrays2040284
BibTeX
@article{Ginsbach2013,
author = {Ginsbach, Philip and Chen, Bowang and Jiang, Yanxiang and Engelter, Stefan T and Grond-Ginsbach, Caspar},
title = {Copy Number Studies in Noisy Samples},
journal = {Microarrays},
year = {2013},
doi = {10.3390/microarrays2040284}
}
EUVIMED