Silicon Microthermocycler for Point-of-Care Analytical Systems: Electro-Thermal Characterization and Optimization for Rapid PCR Amplification
Micromachines · 19.11.2026 · 17 (11) · 1345
DOI: 10.3390/mi17111345 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 19.11.2026. Verfasst von Aljaž Zadravec und 4 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Slovenian Research and Innovation Agency ARIS.
Abstract (Originalsprache)
A sub-microliter silicon microthermocycler platform for rapid point-of-care PCR analytical systems is proposed. To suppress reaction microchamber enzyme adsorption while preserving master mix stoichiometry and amplicon purity, a 24-h bovine serum albumin pre-passivation protocol on developed PDMS–glass microchambers was employed. The system relies on an advanced electro-thermal architecture; it combines a low thermal mass four-tether titanium-on-silicon microheater (Cheater ≈ 8 mJ/K) with an STM32 discrete PID controller and a MAX4211 constant-power regulator. This setup was systematically validated across steady-state plateaus and phase hold time compressions. Thermal characterization revealed a heating rate of 175 °C/s and a cooling rate of 12.5 °C/s (τloaded = 4.04 s). Furthermore, the system maintained sub-degree temperature stability across extended 40-cycle runs (ΔTdrift = +0.001 °C). Optimization of phase thermal parameters (96 °C denaturation, 60 °C annealing, 72 °C extension) and hold times (10 s denaturation, 5 s annealing, 2.5 s extension) enabled successful amplification of a 102-base-pair target within 12 min, achieving 65% runtime reduction compared to conventional benchtop thermocyclers. Lacking real-time fluorescence detection, the prototype currently relies on off-chip secondary qPCR quantification.
Förderung
- Slovenian Research and Innovation Agency ARIS
Zitieren
APA
Zadravec, A., Pečar, B., Caserman, S., Vrtačnik, D., & Možek, M. (2026). Silicon Microthermocycler for Point-of-Care Analytical Systems: Electro-Thermal Characterization and Optimization for Rapid PCR Amplification. Micromachines, 17(11), 1345. https://doi.org/10.3390/mi17111345
Vancouver
Zadravec A, Pečar B, Caserman S, Vrtačnik D, Možek M. Silicon Microthermocycler for Point-of-Care Analytical Systems: Electro-Thermal Characterization and Optimization for Rapid PCR Amplification. Micromachines. 2026;17(11):1345. doi:10.3390/mi17111345
BibTeX
@article{Zadravec2026,
author = {Zadravec, Aljaž and Pečar, Borut and Caserman, Simon and Vrtačnik, Danilo and Možek, Matej},
title = {Silicon Microthermocycler for Point-of-Care Analytical Systems: Electro-Thermal Characterization and Optimization for Rapid PCR Amplification},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {11},
pages = {1345},
doi = {10.3390/mi17111345}
}