An FBG-Based Miniature Force-Sensing Retractor for In Vivo Measurement of Rat Lumbar Nerve Root Traction Force and Injury Assessment
Micromachines · 18.11.2026 · 17 (11) · 1341
DOI: 10.3390/mi17111341 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 18.11.2026. Verfasst von Jixin Li und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Tianjin Health Research Project, Beichen District Health System Science and Technology Project.
Abstract (Originalsprache)
Miniature tools for quantitative measurement of nerve root traction force during posterior lumbar surgery remain limited, restricting objective evaluation of the relationship between traction loading and nerve root injury. In this study, we developed a miniature force-sensing retractor based on fiber Bragg grating (FBG) technology for in vivo measurement of rat lumbar nerve root traction force. The FBG sensing element was encapsulated on the loading side of the miniature retractor and calibrated using standard weight loading. A displacement-controlled rat lumbar nerve root traction model was established to simulate lateral nerve root retraction during posterior lumbar surgery. Rats were assigned to Sham, Mild, Moderate, and Severe groups with predefined lateral displacements of 0, 0.36, 0.72, and 1.08 mm, respectively, maintained for 10 min. Mechanical calibration demonstrated a linear FBG response using an origin-constrained regression model, with a sensitivity of 3.62 nm/N and a theoretical force resolution of approximately 0.006 N. The group-representative steady-state traction forces corresponding to the Mild, Moderate, and Severe groups were approximately 0.09, 0.22, and 0.45 N, respectively. Different traction levels were associated with functional and histological changes at postoperative Day 28. The Severe group showed persistent myelin damage, increased F4/80-positive area, and reduced NF-200-positive area. This study validates the feasibility of an FBG-based miniature force-sensing retractor for quantitative in vivo measurement of nerve root traction force and provides an experimental tool for investigating the biomechanical relationship between traction loading and nerve root injury responses.
Förderung
- The Tianjin Health Research Project
- Beichen District Health System Science and Technology Project
Zitieren
APA
Li, J., Miao, J., Lan, J., Wang, M., & Liao, B. (2026). An FBG-Based Miniature Force-Sensing Retractor for In Vivo Measurement of Rat Lumbar Nerve Root Traction Force and Injury Assessment. Micromachines, 17(11), 1341. https://doi.org/10.3390/mi17111341
Vancouver
Li J, Miao J, Lan J, Wang M, Liao B. An FBG-Based Miniature Force-Sensing Retractor for In Vivo Measurement of Rat Lumbar Nerve Root Traction Force and Injury Assessment. Micromachines. 2026;17(11):1341. doi:10.3390/mi17111341
BibTeX
@article{Li2026,
author = {Li, Jixin and Miao, Jun and Lan, Jie and Wang, Min and Liao, Bangquan},
title = {An FBG-Based Miniature Force-Sensing Retractor for In Vivo Measurement of Rat Lumbar Nerve Root Traction Force and Injury Assessment},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {11},
pages = {1341},
doi = {10.3390/mi17111341}
}
EUVIMED