Fixed-Bias Stream Computing in Filamentary RRAM Crossbars: A Measurement-Calibrated Device–Circuit Study

Melika Morsali, Pranav Choori, Ethan C. Ahn, Mircea R. Stan

Micromachines · 30.10.2026 · 17 (11) · 1269

DOI: 10.3390/mi17111269 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 30.10.2026. Verfasst von Melika Morsali und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Semiconductor Research Corporation, University of Virginia, George Mason University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Filamentary metal–oxide RRAM conducts through a tunneling gap for which the current grows exponentially with bias, so its Read-range I–V characteristic follows a sinh(V/V0) law. This introduces a systematic, input-dependent multiply–accumulate (MAC) error when used in analog Compute-in-Memory (CiM) accelerators with inputs encoded as voltage amplitudes. Because the nonlinearity also varies with resistance state, a single correction factor cannot generally compensate for all programmed weights. We present a measurement-calibrated device-to-circuit study of this error and show how it can be mitigated by replacing voltage-amplitude inputs with fixed-bias time-domain inputs, as in Asynchronous Stream Computing (ASC), which uses constant-amplitude sigma–delta streams. RRAM samples from two independent processes, Pt/Ti/HfO2/Ta/Pt and Al/TiO2/Au/Ti, are characterized, and the Stanford compact model is calibrated to each process. Together with two published parameter sets, the fitted nonlinearity coefficient V0 spans 0.29–0.55 V across four stacks and varies with resistance state within individual devices. In 65 nm circuit simulations, voltage-amplitude encoding incurs up to 30% relative error in a single cell and approximately 8.5% full-scale-normalized error in single-bitline crossbars of 4 to 256 rows. At a 5 ms accumulation window, ASC reduces the array error to 0.4–0.8% with ideal-integrator readout and 0.8–2.3% with transistor-level AΣΔM readout. Under measured device variability, group-balanced Monte Carlo simulations yield 7.6–9.2% analog error versus 0.5–0.7% ASC error. Wire resistance reduces the fixed-bias advantage but does not eliminate it within the simulated conditions. First-order energy estimates identify accumulation time and cell read current as important costs, while practical implementation also requires wordline drivers and high-ratio current division.

Förderung

  • Semiconductor Research Corporation
  • University of Virginia
  • George Mason University

Zitieren

APA

Morsali, M., Choori, P., Ahn, E. C., & Stan, M. R. (2026). Fixed-Bias Stream Computing in Filamentary RRAM Crossbars: A Measurement-Calibrated Device–Circuit Study. Micromachines, 17(11), 1269. https://doi.org/10.3390/mi17111269

Vancouver

Morsali M, Choori P, Ahn EC, Stan MR. Fixed-Bias Stream Computing in Filamentary RRAM Crossbars: A Measurement-Calibrated Device–Circuit Study. Micromachines. 2026;17(11):1269. doi:10.3390/mi17111269

BibTeX
@article{Morsali2026,
  author = {Morsali, Melika and Choori, Pranav and Ahn, Ethan C. and Stan, Mircea R.},
  title = {Fixed-Bias Stream Computing in Filamentary RRAM Crossbars: A Measurement-Calibrated Device–Circuit Study},
  journal = {Micromachines},
  year = {2026},
  volume = {17},
  number = {11},
  pages = {1269},
  doi = {10.3390/mi17111269}
}
Kostenlos starten →