A Dual-Electrode Piezoelectric Micromachined Ultrasonic Transducer for Ring-Down-Based Helium Concentration Measurement
Micromachines · 30.10.2026 · 17 (11) · 1255
DOI: 10.3390/mi17111255 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 30.10.2026. Verfasst von Tong Zhou und 3 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chongqing Natural Science Foundation, Chongqing University of Science and Technology.
Abstract (Originalsprache)
Compact sensing systems can support the preparation and dilution of helium–air mixtures. This study presents a dual-electrode piezoelectric micromachined ultrasonic transducer (PMUT) for helium concentration calibration using its transient response. The inner electrode excites the membrane, and the outer ring electrode detects the response, enabling the amplitude-envelope area, fitted decay rate, and band-summed spectral index to be extracted from the same waveform. The PMUT comprises an aluminum nitride (AlN) piezoelectric layer and molybdenum electrodes on a silicon-on-insulator (SOI) substrate and was fabricated using a complementary metal–oxide–semiconductor (CMOS)-compatible process. Over 60–80 vol% helium, the fitted decay rate increased with an endpoint-based sensitivity of approximately 5.8 × 102 s−1 per vol%. For the measured concentrations within the 30–90 vol% interval, the spectral index exhibited a linear relationship with R2 = 0.9888 and an endpoint-based sensitivity of −0.21 V2 per vol%; the actual calibration points spanned 33.3–81.8 vol%. The envelope area decreased at higher helium fractions. These results establish concentration calibration in helium–air mixtures using a single PMUT and fixed-frequency excitation without frequency sweeps during measurement.
Förderung
- Chongqing Natural Science Foundation
- Chongqing University of Science and Technology
Zitieren
APA
Zhou, T., Lu, L., He, X., & Zhang, F. (2026). A Dual-Electrode Piezoelectric Micromachined Ultrasonic Transducer for Ring-Down-Based Helium Concentration Measurement. Micromachines, 17(11), 1255. https://doi.org/10.3390/mi17111255
Vancouver
Zhou T, Lu L, He X, Zhang F. A Dual-Electrode Piezoelectric Micromachined Ultrasonic Transducer for Ring-Down-Based Helium Concentration Measurement. Micromachines. 2026;17(11):1255. doi:10.3390/mi17111255
BibTeX
@article{Zhou2026,
author = {Zhou, Tong and Lu, Lanwei and He, Xiangting and Zhang, Feng},
title = {A Dual-Electrode Piezoelectric Micromachined Ultrasonic Transducer for Ring-Down-Based Helium Concentration Measurement},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {11},
pages = {1255},
doi = {10.3390/mi17111255}
}