EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance Evaluation of a Sandwich-Structured CNT/Graphene–TPU Nanofiber Strain Sensor for Wearable Deformation Monitoring

Heng Su, Shengbin Cao iD, Xue Zhang iD, Zeyu Liu, Xiaosong Liu

Micromachines · 14.08.2026 · 17 (8) · 959

DOI: 10.3390/mi17080959 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 14.08.2026. Verfasst von Heng Su und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Art and Design, Shanghai Dianji University, Shanghai 201306, China. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the State Key Laboratory of Advanced Fiber Materials, State Key Laboratory of Advanced Fiber Materials at Donghua University in China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flexible strain sensors require both a responsive conductive network and a mechanically compliant supporting structure. In this study, a sandwich-structured carbon nanotube (CNT)/graphene–thermoplastic polyurethane (TPU) nanofiber strain sensor was fabricated by electrospinning, spray-coating, pre-stretching, and hot-pressing. Field-emission scanning electron microscopy was used to examine the nanofiber and coated-fiber morphology, while energy-dispersive X-ray spectroscopy was used only to describe elemental distribution. The electrical response was quantitatively evaluated under tensile deformation. The sensor exhibited piecewise gauge factors of approximately 47.3, 269.6, and 613.8 over strain ranges of 0–20%, 20–45%, and 45–60%, respectively. The response and recovery times were approximately 120 and 180 ms, and the electrical response remained observable over 5000 loading–unloading cycles at 20% strain. Qualitative demonstrations involving finger-bending, elbow-bending, pulse, grasping, walking, and repeated pressing produced distinguishable resistance-time patterns. These results indicate the potential of the CNT/graphene–TPU device for wearable deformation monitoring.

Schlagwörter

Stichwörter der Autor:innen

TPU nanofiberscarbon nanotubesflexible strain sensorgraphenesandwich structure

Autor:innen und Institutionen

  • School of Art and Design, Shanghai Dianji University, Shanghai 201306, China.
  • School of Materials Science and Engineering, Shanghai Dianji University, Shanghai 201306, China.
  • College of Materials Science and Engineering, Donghua University, Shanghai 201620, China.
  • School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • Oxford Suzhou Centre for Advanced Research, Suzhou 215123, China.

ORCID-Profile: Shengbin Cao, Xue Zhang

Förderung

  • the State Key Laboratory of Advanced Fiber Materials
  • State Key Laboratory of Advanced Fiber Materials at Donghua University in China

Zitieren

APA

Su, H., Cao, S., Zhang, X., Liu, Z., & Liu, X. (2026). Performance Evaluation of a Sandwich-Structured CNT/Graphene–TPU Nanofiber Strain Sensor for Wearable Deformation Monitoring. Micromachines, 17(8), 959. https://doi.org/10.3390/mi17080959

Vancouver

Su H, Cao S, Zhang X, Liu Z, Liu X. Performance Evaluation of a Sandwich-Structured CNT/Graphene–TPU Nanofiber Strain Sensor for Wearable Deformation Monitoring. Micromachines. 2026;17(8):959. doi:10.3390/mi17080959

BibTeX
@article{Su2026,
  author = {Su, Heng and Cao, Shengbin and Zhang, Xue and Liu, Zeyu and Liu, Xiaosong},
  title = {Performance Evaluation of a Sandwich-Structured CNT/Graphene–TPU Nanofiber Strain Sensor for Wearable Deformation Monitoring},
  journal = {Micromachines},
  year = {2026},
  volume = {17},
  number = {8},
  pages = {959},
  doi = {10.3390/mi17080959}
}
Kostenlos starten →