A Cascaded Dual Spiral Microfluidic Chip for Continuous Separation of Multicomponent Microparticles
Micromachines · 13.04.2026 · 17 (4) · 469
DOI: 10.3390/mi17040469 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 13.04.2026. Verfasst von Renxuan Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Microelectronics, Shanghai University, Shanghai 200444, China. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, Natural Science Foundation of Shanghai.
Abstract (Originalsprache)
Inertial microfluidics is promising for the high throughput, label-free continuous separation of multicomponent microparticles. However, conventional single spiral microchannels struggle to separate three or more particle types, while traditional cascaded systems relying on sheath fluids or multiple pumps suffer from increased operational complexity. To address this, we propose a cascaded dual spiral microfluidic chip based on passive flow resistance matching. Driven by a single syringe pump without sheath flow, it achieves continuous sorting of three particle types. An adaptive flow resistance network is incorporated: the first stage channel maintains high velocity to preferentially extract large particles via strong inertial lift forces. The fluid then enters the second stage through a predetermined geometric resistance for automatic deceleration. Experiments demonstrate that at 1.6 mL/min, the system achieves continuous separation of a 1:10:10 mixture of 15, 10, and 5 µm microparticles. The 15 µm target recovery rate reaches 92%, while the collection purities for 10 µm and 5 µm particles exceed 98% and 99%, respectively. This purely passive fluidic architecture simplifies cascaded sorting, providing a robust engineering solution for complex multicomponent sample preprocessing.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Microelectronics, Shanghai University, Shanghai 200444, China.
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
- Shanghai Frontier Innovation Research Institute, Shanghai 201108, China.
ORCID-Profile: Ting Liu
Förderung
- National Natural Science Foundation of China
- Science and Technology Commission of Shanghai Municipality
- Natural Science Foundation of Shanghai
Zitieren
APA
Zhang, R., Liu, T., Zhao, J., & Cai, G. (2026). A Cascaded Dual Spiral Microfluidic Chip for Continuous Separation of Multicomponent Microparticles. Micromachines, 17(4), 469. https://doi.org/10.3390/mi17040469
Vancouver
Zhang R, Liu T, Zhao J, Cai G. A Cascaded Dual Spiral Microfluidic Chip for Continuous Separation of Multicomponent Microparticles. Micromachines. 2026;17(4):469. doi:10.3390/mi17040469
BibTeX
@article{Zhang2026,
author = {Zhang, Renxuan and Liu, Ting and Zhao, Jianlong and Cai, Gaozhe},
title = {A Cascaded Dual Spiral Microfluidic Chip for Continuous Separation of Multicomponent Microparticles},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {4},
pages = {469},
doi = {10.3390/mi17040469}
}
EUVIMED