A Wearable Multi-Modal Measurement System with Self-Developed IMUs and Plantar Pressure Sensors for Real-Time Gait Recognition
Micromachines · 19.03.2026 · 17 (3) · 371
DOI: 10.3390/mi17030371 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 19.03.2026. Verfasst von Xiuyu Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Measurement Technology and Intelligent Control Institute, School of Instrumentation Science and Engineering, Harbin Institute of Technolog…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
To address the limitations of existing wearable gait recognition, such as drift in static actions and difficulty in recognizing transition states, this paper proposed a gait recognition system based on the data fusion of MEMS Inertial Measurement Units (IMUs) and flexible plantar pressure sensors. A low-power wearable device comprising four inertial and two pressure sensing nodes was developed to achieve synchronized multi-source data collection. Regarding the algorithm, a sensor-characteristic-based two-stage hierarchical framework was constructed. The first stage utilized plantar pressure features to efficiently decouple static postures from dynamic gaits. The second stage employed a lightweight Support Vector Machine combined with a Finite State Machine for static and transitional actions, while an ensemble learning model based on Soft Voting was used for complex dynamic gaits. Experimental results under Leave-One-Out Cross-Validation demonstrate a comprehensive recognition accuracy of 96.17%, with 100% accuracy for standing and 97% for sit-to-stand transitions. These findings validate the significant advantages of the multi-modal fusion approach in enhancing the robustness and generalization capabilities of gait recognition.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Electrical Measurement Technology and Intelligent Control Institute, School of Instrumentation Science and Engineering, Harbin Institute of Technology, Harbin 150080, China.
- The 49th Research Institute of China Electronics Technology Group Corporation, Harbin 150028, China.
- Department of Data Science, City University of Hong Kong, Hong Kong, China.
ORCID-Profile: Jingxiao Liao
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Li, X., Gao, Y., Chen, G., Zhang, M., Liao, J., Wang, Z., & Sun, J. (2026). A Wearable Multi-Modal Measurement System with Self-Developed IMUs and Plantar Pressure Sensors for Real-Time Gait Recognition. Micromachines, 17(3), 371. https://doi.org/10.3390/mi17030371
Vancouver
Li X, Gao Y, Chen G, Zhang M, Liao J, Wang Z, et al. A Wearable Multi-Modal Measurement System with Self-Developed IMUs and Plantar Pressure Sensors for Real-Time Gait Recognition. Micromachines. 2026;17(3):371. doi:10.3390/mi17030371
BibTeX
@article{Li2026,
author = {Li, Xiuyu and Gao, Yunong and Chen, Guanzhong and Zhang, Meiyan and Liao, Jingxiao and Wang, Zhaoyun and Sun, Jinwei},
title = {A Wearable Multi-Modal Measurement System with Self-Developed IMUs and Plantar Pressure Sensors for Real-Time Gait Recognition},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {3},
pages = {371},
doi = {10.3390/mi17030371}
}