Experimental Investigation of a Tubular Front Cavity for Wind Noise Suppression in MEMS Microphones of Mobile Devices

Chengpu Sun, Shikun Wei, Bilong Liu

Micromachines · 14.03.2026 · 17 (3) · 357

DOI: 10.3390/mi17030357 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 14.03.2026. Verfasst von Chengpu Sun und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical & Automobile Engineering, Qingdao University of Technology, No. 777 Jialingjiang Road, Qingdao 266520, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Science Fundation of China, National Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wind-induced noise remains a critical engineering challenge for MEMS microphones in compact consumer electronics such as smartphones, where spatial constraints limit conventional noise control solutions. This study experimentally investigates the suppression of flow-induced wind noise by a straight tube serving as the front cavity of a microphone, using a precision measurement microphone for data acquisition. Controlled experiments were conducted in both a flow duct for parametric isolation and an anechoic chamber for real-world validation. Results demonstrate a strong diameter-dependent effect: for a 1 mm diameter, increasing tube length significantly reduces noise power spectral density and steepens high-frequency roll-off via enhanced internal viscous and thermal dissipation. This effect weakens for a 2 mm diameter and becomes negligible for a 3 mm diameter, where noise is dominated by external flow excitation at the tube inlet rather than internal propagation. Therefore, extending tube length is an effective noise control strategy only for small-diameter cavities. Furthermore, while increased wind speed and oblique incidence elevate PSD, a longer tube reduces this sensitivity. Because acoustic transmission loss—including potential effects like aperture diffraction and impedance mismatch—was not measured, any resulting improvement in the effective signal-to-noise ratio is strictly presented as a hypothesis requiring future electroacoustic validation. The consistent findings across both experimental environments provide clear design guidance: for compact MEMS microphone systems in portable devices, elongating the front cavity is a viable passive noise control method only when the cavity diameter is sufficiently small (

Schlagwörter

Stichwörter der Autor:innen

duct flow experimentmicrophonetubular front cavitywind noise suppression

Autor:innen und Institutionen

  • School of Mechanical & Automobile Engineering, Qingdao University of Technology, No. 777 Jialingjiang Road, Qingdao 266520, China.

Förderung

  • the National Science Fundation of China
  • National Science Foundation of China

Zitieren

APA

Sun, C., Wei, S., & Liu, B. (2026). Experimental Investigation of a Tubular Front Cavity for Wind Noise Suppression in MEMS Microphones of Mobile Devices. Micromachines, 17(3), 357. https://doi.org/10.3390/mi17030357

Vancouver

Sun C, Wei S, Liu B. Experimental Investigation of a Tubular Front Cavity for Wind Noise Suppression in MEMS Microphones of Mobile Devices. Micromachines. 2026;17(3):357. doi:10.3390/mi17030357

BibTeX
@article{Sun2026,
  author = {Sun, Chengpu and Wei, Shikun and Liu, Bilong},
  title = {Experimental Investigation of a Tubular Front Cavity for Wind Noise Suppression in MEMS Microphones of Mobile Devices},
  journal = {Micromachines},
  year = {2026},
  volume = {17},
  number = {3},
  pages = {357},
  doi = {10.3390/mi17030357}
}