A Compact 380 GHz Zero-Bias Schottky Diode Detector for High-Sensitivity Radiometer Applications
Micromachines · 13.03.2026 · 17 (3) · 352
DOI: 10.3390/mi17030352 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 13.03.2026. Verfasst von Huilin Tang und 2 weiteren Autor:innen. Beteiligte Einrichtung: The CAS Key Laboratory of Microwave Remote Sensing, National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: HY-2E/F Satellite Calibration Radiometer.
Abstract (Originalsprache)
Reliable terahertz radiometer receiver systems demand detectors that combine high sensitivity with structural robustness. This paper presents the design, fabrication, and characterization of a 380 GHz zero-bias detector based on an ACST Schottky diode. The detector uses a high-impedance grounding topology to reduce parasitic resonances and enhance output stability. A compact U-shaped waveguide transition is adopted to realize an inline port configuration. This configuration simplifies system integration. Measurements demonstrate a peak voltage responsivity of 2318 V/W and a linearity of 0.9996 at 380 GHz, validating the effectiveness of the proposed design. This work establishes a practical design approach for zero-bias terahertz detectors and supports future high-frequency radiometer and sensing applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The CAS Key Laboratory of Microwave Remote Sensing, National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
ORCID-Profile: Huilin Tang, Yongsheng Deng
Förderung
- HY-2E/F Satellite Calibration Radiometer
Zitieren
APA
Tang, H., Deng, Y., & Zhang, D. (2026). A Compact 380 GHz Zero-Bias Schottky Diode Detector for High-Sensitivity Radiometer Applications. Micromachines, 17(3), 352. https://doi.org/10.3390/mi17030352
Vancouver
Tang H, Deng Y, Zhang D. A Compact 380 GHz Zero-Bias Schottky Diode Detector for High-Sensitivity Radiometer Applications. Micromachines. 2026;17(3):352. doi:10.3390/mi17030352
BibTeX
@article{Tang2026,
author = {Tang, Huilin and Deng, Yongsheng and Zhang, Dehai},
title = {A Compact 380 GHz Zero-Bias Schottky Diode Detector for High-Sensitivity Radiometer Applications},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {3},
pages = {352},
doi = {10.3390/mi17030352}
}
EUVIMED