Übersichtsarbeit in der Zeitschrift Micromachines, online erschienen am 28.02.2026. Verfasst von Anita Ioana Visan und 2 weiteren Autor:innen. Beteiligte Einrichtung: National Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomiştilor 409, 077125 Magurele, Romania. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 306 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Wundversorgung
Abstract (Originalsprache)
Chronic and infected wounds remain a major clinical challenge due to their dynamic microenvironments and the lack of real-time diagnostic feedback in conventional dressings. Recent advances in stimuli-responsive nanomaterial-based biosensors have enabled the development of smart wound-care systems capable of continuous monitoring and on-demand therapeutic intervention. This review systematically summarizes progress in nanomaterial-enabled wound biosensing strategies, with a focus on pH, reactive oxygen species, and temperature nanosensors, which serve as key indicators of infection, inflammation, and healing status. We discuss the sensing mechanisms and functional roles of diverse nanomaterials. A particular focus is placed on emerging multimodal and theranostic platforms which integrate biochemical and physical sensing with controlled drug release, photothermal or photodynamic therapy, and redox regulation. These systems represent a shift from passive wound monitoring toward closed-loop, adaptive wound management. Also, future perspectives are outlined, highlighting the convergence of nanomaterials, self-powered electronics, and intelligent data processing as a pathway toward personalized and precision wound care.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomiştilor 409, 077125 Magurele, Romania.
- Center for Nanotechnology and Nanosensors, Department of Microelectronics and Biomedical Engineering, Technical University of Moldova, 168 Ștefan cel Mare Avenue, MD-2004 Chisinau, Moldova.
ORCID-Profile: Anita Ioana Visan, Adrian Birnaz, Irina Negut
Zitieren
APA
Visan, A. I., Birnaz, A., & Negut, I. (2026). Stimuli-Responsive Nanomaterial-Based Biosensor Structures for Wound Care: pH, ROS, and Temperature Sensing Strategies. Micromachines, 17(3), 306. https://doi.org/10.3390/mi17030306
Vancouver
Visan AI, Birnaz A, Negut I. Stimuli-Responsive Nanomaterial-Based Biosensor Structures for Wound Care: pH, ROS, and Temperature Sensing Strategies. Micromachines. 2026;17(3):306. doi:10.3390/mi17030306
BibTeX
@article{Visan2026,
author = {Visan, Anita Ioana and Birnaz, Adrian and Negut, Irina},
title = {Stimuli-Responsive Nanomaterial-Based Biosensor Structures for Wound Care: pH, ROS, and Temperature Sensing Strategies},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {3},
pages = {306},
doi = {10.3390/mi17030306}
}
EUVIMED