On-Wafer Gate Screening Test for Improved Pre-Reliability in p-GaN HEMTs
Micromachines · 29.07.2025 · 16 (8) · 873
DOI: 10.3390/mi16080873 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 29.07.2025. Verfasst von Giovanni Giorgino und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering "Enzo Ferrari", Università di Modena e Reggio Emilia, 41125 Modena, Italy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In this paper, preliminary gate reliability of p-GaN HEMTs under high positive gate bias is studied. Gate robustness is of great interest both from an academic and industrial point of view; in fact, different tests and models can be explored to estimate the device lifetime, which must meet some minimum product requirements, as specified by international standards (AEC Q101, JESD47, etc.). However, reliability characterizations are usually time-consuming and are performed in parallel on multiple packaged devices. Therefore, it would be useful to have a faster method to screen out weaker gate trials, already on-wafer, before reaching the packaging step. For this purpose, a room-temperature stress procedure is presented and described in detail. Then, this screening test is applied to devices with a reference gate process, and, as a result, high gate leakage degradation is observed. Afterwards, a different process implementing a dielectric layer between p-GaN and gate metal is evaluated, highlighting the improved behavior during the stress test. However, it is also observed that devices with this process suffer from very high drain leakage, and this effect is then studied and understood through TCAD (technology computer-aided design) simulations. Finally, the effect of a surface treatment performed on the p-GaN is analyzed, showing improved gate pre-reliability while maintaining low drain leakage.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Engineering "Enzo Ferrari", Università di Modena e Reggio Emilia, 41125 Modena, Italy.
- STMicroelectronics, 95121 Catania, Italy.
- STMicroelectronics, 37071 Tours, France.
ORCID-Profile: Giovanni Giorgino, Cristina Miccoli, Hyon-Ju Chauveau, Alessandro Chini
Zitieren
APA
Giorgino, G., Miccoli, C., Cioni, M., Reina, S., Wakrim, T., Guillon, V., Sama, N. Y., Gaillard, P., Zeghouane, M., Chauveau, H. J., Castagna, M. E., Constant, A., Iucolano, F., & Chini, A. (2025). On-Wafer Gate Screening Test for Improved Pre-Reliability in p-GaN HEMTs. Micromachines, 16(8), 873. https://doi.org/10.3390/mi16080873
Vancouver
Giorgino G, Miccoli C, Cioni M, Reina S, Wakrim T, Guillon V, et al. On-Wafer Gate Screening Test for Improved Pre-Reliability in p-GaN HEMTs. Micromachines. 2025;16(8):873. doi:10.3390/mi16080873
BibTeX
@article{Giorgino2025,
author = {Giorgino, Giovanni and Miccoli, Cristina and Cioni, Marcello and Reina, Santo and Wakrim, Tariq and Guillon, Virgil and Sama, Nossikpendou Yves and Gaillard, Pauline and Zeghouane, Mohammed and Chauveau, Hyon-Ju and Castagna, Maria Eloisa and Constant, Aurore and Iucolano, Ferdinando and Chini, Alessandro},
title = {On-Wafer Gate Screening Test for Improved Pre-Reliability in p-GaN HEMTs},
journal = {Micromachines},
year = {2025},
volume = {16},
number = {8},
pages = {873},
doi = {10.3390/mi16080873}
}
EUVIMED