EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Robust Normally Closed Pneumatic Valve for Integrated Microfluidic Flow Control

Minggan Li iD, Siqin Dong iD

Micromachines · 29.12.2024 · 16 (1) · 34

DOI: 10.3390/mi16010034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 29.12.2024. Verfasst von Minggan Li und 1 weiteren Autor:innen. Beteiligte Einrichtung: Zepto Life Technology Inc., 1000 Westgate Drive, St. Paul, MN 55114, USA. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate fluid management in microfluidic-based point-of-care testing (POCT) devices is critical. Fluids must be gated and directed in precise sequences to facilitate desired biochemical reactions and signal detection. Pneumatic valves are widely utilized for fluid gating due to their flexibility and simplicity. However, the development of reliable normally closed pneumatic valves remains challenging, despite their increasing demand in advanced POCT applications to prevent uncontrolled fluid flow. Existing normally closed valves often suffer from poor reliability and lack precise control over fluid opening pressure, due to the uncontrolled stretching of the elastomer during assembly. In this study, we propose and develop a robust method for normally closed valves. By precisely controlling the pre-stretching of the elastomer, we achieve reliable valve closure and accurate control of the opening pressure. A robust normally closed valve was designed and fabricated, and its pneumatic opening pressure was systematically studied. Experimental validations were conducted to demonstrate the reliability and effectiveness of the proposed design.

Schlagwörter

Stichwörter der Autor:innen

in vitro diagnostic (IVD)lab on a chipmicrofluidicnormally closed valve

Autor:innen und Institutionen

  • Zepto Life Technology Inc., 1000 Westgate Drive, St. Paul, MN 55114, USA.

ORCID-Profile: Minggan Li, Siqin Dong

Zitieren

APA

Li, M., & Dong, S. (2024). A Robust Normally Closed Pneumatic Valve for Integrated Microfluidic Flow Control. Micromachines, 16(1), 34. https://doi.org/10.3390/mi16010034

Vancouver

Li M, Dong S. A Robust Normally Closed Pneumatic Valve for Integrated Microfluidic Flow Control. Micromachines. 2024;16(1):34. doi:10.3390/mi16010034

BibTeX
@article{Li2024,
  author = {Li, Minggan and Dong, Siqin},
  title = {A Robust Normally Closed Pneumatic Valve for Integrated Microfluidic Flow Control},
  journal = {Micromachines},
  year = {2024},
  volume = {16},
  number = {1},
  pages = {34},
  doi = {10.3390/mi16010034}
}