In Situ Potentiometric Monitoring of Nitrate Removal from Aqueous Solution by Activated Carbon and Ion Exchange Resin
Micromachines · 12.11.2024 · 15 (11) · 1366
DOI: 10.3390/mi15111366 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 12.11.2024. Verfasst von José Manuel Olmos und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, University of Murcia, 30100 Murcia, Spain. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia, Innovación y Universidades, Ministerio de Ciencia e Innovación.
Abstract (Originalsprache)
A nitrate selective electrode was used for real-time in situ potentiometric monitoring of a batch nitrate removal process using activated carbon and ion exchange resin. A plasticized polymeric membrane consisting of polyvinyl chloride, 2-nitrophenyl octyl ether and tridodecyl methyl ammonium chloride was incorporated into an ion-selective electrode body. First, the dynamic potential response of the electrode to nitrate was investigated. Two commercial activated carbons with different physical properties were then tested. Nitrate removal with these carbons was monitored potentiometrically using several nitrate concentrations. The extreme turbidity of the solutions was not a drawback during potentiometric monitoring of the process, which is a clear advantage over other methods such as optical monitoring. The potential versus time recordings were converted into nitrate concentration versus time plots, which were evaluated with different adsorption kinetic models. A pseudo-second order kinetic model for nitrate adsorption on both activated carbons was found to fit the experimental data very well. The values of the kinetic parameters were very different between the two activated carbons. The proposed methodology was also satisfactorily applied to the study of nitrate removal by an ion exchange resin. In this case, the experimental results clearly follow a pseudo-first order kinetic model. Potential applications of the proposed methodology for monitoring nitrate removal in real water samples are discussed.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Analytical Chemistry, University of Murcia, 30100 Murcia, Spain.
ORCID-Profile: Joaquín Ángel Ortuño
Förderung
- Ministerio de Ciencia, Innovación y Universidades
- Ministerio de Ciencia e Innovación
Zitieren
APA
Olmos, J. M., Gil, L., & Ortuño, J. Á. (2024). In Situ Potentiometric Monitoring of Nitrate Removal from Aqueous Solution by Activated Carbon and Ion Exchange Resin. Micromachines, 15(11), 1366. https://doi.org/10.3390/mi15111366
Vancouver
Olmos JM, Gil L, Ortuño JÁ. In Situ Potentiometric Monitoring of Nitrate Removal from Aqueous Solution by Activated Carbon and Ion Exchange Resin. Micromachines. 2024;15(11):1366. doi:10.3390/mi15111366
BibTeX
@article{Olmos2024,
author = {Olmos, José Manuel and Gil, Lucía and Ortuño, Joaquín Ángel},
title = {In Situ Potentiometric Monitoring of Nitrate Removal from Aqueous Solution by Activated Carbon and Ion Exchange Resin},
journal = {Micromachines},
year = {2024},
volume = {15},
number = {11},
pages = {1366},
doi = {10.3390/mi15111366}
}