EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and Implementation of a Four-Unit Array Piezoelectric Bionic MEMS Vector Hydrophone

Shuzheng Shi, Xiaoyong Zhang, Zhanying Wang, Liyong Ma iD, Kai Kang, Yongjun Pang, Hong Ma, Jinjiang Hu iD

Micromachines · 14.04.2024 · 15 (4) · 524

DOI: 10.3390/mi15040524 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 14.04.2024. Verfasst von Shuzheng Shi und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Hebei University of Architecture, Zhangjiakou 075000, China. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Doctoral Research Start-up of Hebei University of Architectur, Basic Scientific Research Business Project of Colleges and Universities in Hebei Province, Zhangjiakou Basic Research and Talent Training Program Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-performance vector hydrophones have been gaining attention for underwater target-monitoring applications. Nevertheless, there exists the mutual constraint between sensitivity and bandwidth of a single hydrophone. To solve this problem, a four-unit array piezoelectric bionic MEMS vector hydrophone (FPVH) was developed in this paper, which has a cross-beam and a bionic fish-lateral-line-nerve-cell-cilia unit array structure. Simulation analysis and optimization in the design of the bionic microstructure have been performed by COMSOL 6.1 software to determine the structure dimensions and the lead zirconate titanate (PZT) thin film distribution. The FPVH was manufactured using MEMS technology and tested in a standing wave bucket. The results indicate that the FPVH has a sensitivity of up to −167.93 dB@1000 Hz (0 dB = 1 V/μPa), which is 12 dB higher than that of the one-unit piezoelectric MEMS vector hydrophone (OPVH). Additionally, the working bandwidth of the FPVH reaches 20 Hz~1200 Hz, exhibiting a good cosine curve with an 8-shape. This work paves a new way for the development of multi-unit piezoelectric vector hydrophones for underwater acoustic detectors.

Schlagwörter

Stichwörter der Autor:innen

MEMSPZTarray vector hydrophonebionic structuresensitivity

Autor:innen und Institutionen

  • School of Mechanical Engineering, Hebei University of Architecture, Zhangjiakou 075000, China.
  • School of Computer Science and Engineering, North China University of Science and Technology, Tangshan 063210, China.
  • HBIS Group Co., Ltd., Shijiazhuang 050023, China.
  • Department of Intelligence and Automation, Taiyuan University, Taiyuan 030032, China.
  • School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, China.
  • School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China.

ORCID-Profile: Liyong Ma, Jinjiang Hu

Förderung

  • The Doctoral Research Start-up of Hebei University of Architectur
  • Basic Scientific Research Business Project of Colleges and Universities in Hebei Province
  • Zhangjiakou Basic Research and Talent Training Program Project
  • Zhangjiakou City key research and development plan special
  • Doctoral Research Start-up of Hebei University of Architectur

Zitieren

APA

Shi, S., Zhang, X., Wang, Z., Ma, L., Kang, K., Pang, Y., Ma, H., & Hu, J. (2024). Design and Implementation of a Four-Unit Array Piezoelectric Bionic MEMS Vector Hydrophone. Micromachines, 15(4), 524. https://doi.org/10.3390/mi15040524

Vancouver

Shi S, Zhang X, Wang Z, Ma L, Kang K, Pang Y, et al. Design and Implementation of a Four-Unit Array Piezoelectric Bionic MEMS Vector Hydrophone. Micromachines. 2024;15(4):524. doi:10.3390/mi15040524

BibTeX
@article{Shi2024,
  author = {Shi, Shuzheng and Zhang, Xiaoyong and Wang, Zhanying and Ma, Liyong and Kang, Kai and Pang, Yongjun and Ma, Hong and Hu, Jinjiang},
  title = {Design and Implementation of a Four-Unit Array Piezoelectric Bionic MEMS Vector Hydrophone},
  journal = {Micromachines},
  year = {2024},
  volume = {15},
  number = {4},
  pages = {524},
  doi = {10.3390/mi15040524}
}
Kostenlos starten →