Electromagnetic Susceptibility Analysis of the Operational Amplifier to Conducted EMI Injected through the Power Supply Port
Micromachines · 11.01.2024 · 15 (1) · 121
DOI: 10.3390/mi15010121 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 11.01.2024. Verfasst von Peng Huang und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic and Information Engineering, Beihang University, Beijing 100191, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Civil Aircraft Projects of China.
Abstract (Originalsprache)
Operational amplifiers (op-amps) are widely used in circuit systems. The increasing complexity of the power supply network has led to the susceptibility of the power supply port to electromagnetic interference (EMI) in circuit systems. Therefore, it is necessary to investigate the electromagnetic susceptibility (EMS) of op-amps at the power supply port. In this paper, we assessed the effect of EMI on the operational performance of op-amps through the power supply port by a bulk current injection (BCI) method. Firstly, we conducted the continuous sine wave into the power supply port by a current injection probe and measured the change in the offset voltage under EMI. Secondly, we proposed a new method of conducted susceptibility and obtained the susceptibility threshold regularities of the op-amps at the power supply port under the interference of different waveform signals. Our study provided conclusive evidence that EMI reduced the reliability of the op-amp by affecting the offset voltage of op-amps and demonstrated that the sensitivity type of op-amps was peak-sensitive at the power supply port. This study contributed to a deep understanding of the EMS mechanism and guided the design of electromagnetic compatibility (EMC) of op-amps.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electronic and Information Engineering, Beihang University, Beijing 100191, China.
- Research Institute for Frontier Science, Beihang University, Beijing 100191, China.
- No. 24 Research Institute, China Electronics Technology Group Corporation, Chongqing 404100, China.
ORCID-Profile: Peng Huang, Xuchun Hao, Shuguo Xie
Förderung
- National Natural Science Foundation of China
- Civil Aircraft Projects of China
Zitieren
APA
Huang, P., Li, B., Wei, M., Hao, X., Chen, X., Huang, X., Huang, W., Zhou, S., Wen, X., Xie, S., & Su, D. (2024). Electromagnetic Susceptibility Analysis of the Operational Amplifier to Conducted EMI Injected through the Power Supply Port. Micromachines, 15(1), 121. https://doi.org/10.3390/mi15010121
Vancouver
Huang P, Li B, Wei M, Hao X, Chen X, Huang X, et al. Electromagnetic Susceptibility Analysis of the Operational Amplifier to Conducted EMI Injected through the Power Supply Port. Micromachines. 2024;15(1):121. doi:10.3390/mi15010121
BibTeX
@article{Huang2024,
author = {Huang, Peng and Li, Bing and Wei, Mengyuan and Hao, Xuchun and Chen, Xi and Huang, Xiaozong and Huang, Wei and Zhou, Shuling and Wen, Xiaokang and Xie, Shuguo and Su, Donglin},
title = {Electromagnetic Susceptibility Analysis of the Operational Amplifier to Conducted EMI Injected through the Power Supply Port},
journal = {Micromachines},
year = {2024},
volume = {15},
number = {1},
pages = {121},
doi = {10.3390/mi15010121}
}
EUVIMED