Fachartikel in der Zeitschrift Micromachines, online erschienen am 31.10.2023. Verfasst von Tatiana Turcitu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5, Canada. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council, National Science and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microfluidic devices are frequently manufactured with polydimethylsiloxane (PDMS) due to its affordability, transparency, and simplicity. However, high-pressure flow through PDMS microfluidic channels lead to an increase in channel size due to the compliance of the material. As a result, longer response times are required to reach steady flow rates, which increases the overall time required to complete experiments when using a syringe pump. Due to its excellent optical properties and increased rigidity, Norland Optical Adhesive (NOA) has been proposed as a promising material candidate for microfluidic fabrication. This study compares the compliance and deformation properties of three different characteristic sized (width of parallel channels: 100, 40 and 20 µm) microfluidic devices made of PDMS and NOA. The comparison of the microfluidics devices is made based on the Young’s modulus, roughness, contact angle, channel width deformation, flow resistance and compliance. The experimental resistance is estimated through the measurement of the flow at a given pressure and a precision flow meter. The characteristic time of the system is extracted by fitting the two-element resistance-compliance (RC) hydraulic circuit model. The compliance of the microfluidics chips is estimated through the measurement of the characteristic time required for channels to achieve an output flow rate equivalent to that of the input flow rate using a syringe pump and a precision flow meter. The Young modulus was found to be 2 MPa for the PDMS and 1743 MPa for the NOA 63. The surface roughness was found to be higher for the NOA 63 than for the PDMS. The hydrophilicities of materials were found comparable with and without plasma treatment. The results show that NOA devices have lower compliance and deformation than PDMS devices.

Schlagwörter

Stichwörter der Autor:innen

NOA 63PDMSRC hydraulic circuit modelcharacteristic timecompliancecontact anglehydrophilicitymicrofluidicsresistanceroughnessyoung modulus

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5, Canada.

ORCID-Profile: Niko Lee-Yow, Maya Salame, Andy Vinh Le, Marianne Fenech

Förderung

  • Natural Sciences and Engineering Research Council
  • National Science and Engineering Research Council of Canada

Zitieren

APA

Turcitu, T., Armstrong, C. J. K., Lee-Yow, N., Salame, M., Le, A. V., & Fenech, M. (2023). Comparison of PDMS and NOA Microfluidic Chips: Deformation, Roughness, Hydrophilicity and Flow Performance. Micromachines, 14(11), 2033. https://doi.org/10.3390/mi14112033

Vancouver

Turcitu T, Armstrong CJK, Lee-Yow N, Salame M, Le AV, Fenech M. Comparison of PDMS and NOA Microfluidic Chips: Deformation, Roughness, Hydrophilicity and Flow Performance. Micromachines. 2023;14(11):2033. doi:10.3390/mi14112033

BibTeX
@article{Turcitu2023,
  author = {Turcitu, Tatiana and Armstrong, Curtis J K and Lee-Yow, Niko and Salame, Maya and Le, Andy Vinh and Fenech, Marianne},
  title = {Comparison of PDMS and NOA Microfluidic Chips: Deformation, Roughness, Hydrophilicity and Flow Performance},
  journal = {Micromachines},
  year = {2023},
  volume = {14},
  number = {11},
  pages = {2033},
  doi = {10.3390/mi14112033}
}
Kostenlos starten →