EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A High Sensitivity AlN-Based MEMS Hydrophone for Pipeline Leak Monitoring

Baoyu Zhi, Zhipeng Wu, Caihui Chen, Minkan Chen, Xiaoxia Ding, Liang Lou

Micromachines · 14.03.2023 · 14 (3) · 654

DOI: 10.3390/mi14030654 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 14.03.2023. Verfasst von Baoyu Zhi und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Microelectronics, Shanghai University, Shanghai 201800, China. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, a miniaturized, low-cost, low-power and high-sensitivity AlN-based micro-electro-mechanical system (MEMS) hydrophone is proposed for monitoring water pipeline leaks. The proposed MEMS Hydrophone consists of a piezoelectric micromachined ultrasonic transducer (PMUT) array, an acoustic matching layer and a pre-amplifier amplifier circuit. The array has 4 (2 × 2) PMUT elements with a first-order resonant frequency of 41.58 kHz. Due to impedance matching of the acoustic matching layer and the 40 dB gain of the pre-amplifier amplifier circuit, the packaged MEMS Hydrophone has a high sound pressure sensitivity of −170 ± 2 dB (re: 1 V/μPa). The performance with respect to detecting pipeline leaks and locating leak points is demonstrated on a 31 m stainless leaking pipeline platform. The standard deviation (STD) of the hydroacoustic signal and Monitoring Index Efficiency (MIE) are extracted as features of the pipeline leak. A random forest model is trained for accurately classifying the leak and no-leak cases using the above features, and the accuracy of the model is about 97.69%. The cross-correlation method is used to locate the leak point, and the localization relative error is about 10.84% for a small leak of 12 L/min.

Schlagwörter

Stichwörter der Autor:innen

MEMS hydrophonePMUTleak detectionleak localization

Autor:innen und Institutionen

  • School of Microelectronics, Shanghai University, Shanghai 201800, China.
  • The Shanghai Industrial μ Technology Research Institute, Shanghai 201899, China.

Zitieren

APA

Zhi, B., Wu, Z., Chen, C., Chen, M., Ding, X., & Lou, L. (2023). A High Sensitivity AlN-Based MEMS Hydrophone for Pipeline Leak Monitoring. Micromachines, 14(3), 654. https://doi.org/10.3390/mi14030654

Vancouver

Zhi B, Wu Z, Chen C, Chen M, Ding X, Lou L. A High Sensitivity AlN-Based MEMS Hydrophone for Pipeline Leak Monitoring. Micromachines. 2023;14(3):654. doi:10.3390/mi14030654

BibTeX
@article{Zhi2023,
  author = {Zhi, Baoyu and Wu, Zhipeng and Chen, Caihui and Chen, Minkan and Ding, Xiaoxia and Lou, Liang},
  title = {A High Sensitivity AlN-Based MEMS Hydrophone for Pipeline Leak Monitoring},
  journal = {Micromachines},
  year = {2023},
  volume = {14},
  number = {3},
  pages = {654},
  doi = {10.3390/mi14030654}
}
Kostenlos starten →