Acoustic and Inertial Sensor Techniques for Top Submerged Lance (TSL) Technology: A Practical Framework for Characterizing Bubble Dynamics Under High-Temperature Conditions
Metals · 11.05.2026 · 16 (5) · 519
DOI: 10.3390/met16050519 ↗Kurz gefasst
Fachartikel in der Zeitschrift Metals, online erschienen am 11.05.2026. Verfasst von Avinash Kandalam und 5 weiteren Autor:innen. Die Arbeit nennt 87 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: BMBF, Germany.
Abstract (Originalsprache)
Top Submerged Lance (TSL) technology is widely used in non-ferrous smelting, yet in-situ bath dynamics remain challenging to quantify because the process operates in a closed, high-temperature, highly turbulent and optically inaccessible environment. The absence of direct diagnostics limits the ability to relate operating conditions to bubble dynamics, gas penetration and bath agitation and constrains validation of multiphase CFD models under realistic conditions. This study introduces a multimodal sensing framework that combines spectral acoustic analysis with lance-mounted inertial motion sensing to characterize dynamic bath behavior across cold-model, laboratory-scale and pilot-scale systems. Water-glycerin experiments establish repeatable acoustic signatures of individual bubble-collapse events, with dominant emission bands in the 300–900 Hz range and higher-frequency components extending into the kilohertz domain. High-temperature laboratory trials using fayalitic slag reproduce these frequency regions while exhibiting depth-dependent attenuation and clear spectral separation between submerged and non-submerged lance operation. Power Spectral Density (PSD) and cumulative spectral power analyses resolve the influence of gas flow rate and lance submersion depth on acoustic spectral power distribution, while inertial measurements capture corresponding increases in vertical lance acceleration associated with back-pressure fluctuations. Pilot-scale trials at 120 Nm3/h air and 13 L/h diesel confirm that shallow lance submersion substantially increases measured acoustic spectral power below 3 kHz, whereas deeper penetration enhances periodic vertical acceleration response measured by the inertial sensor. The combined acoustic-inertial methodology provides a physically interpretable and cross-scale framework for assessing bubble collapse activity, plume interaction and bath agitation under high-temperature TSL conditions. The approach enables frequency-based diagnostics that can be systematically compared with CFD predictions of plume oscillation and collapse-related dynamics. Once baseline frequency ranges are established for a given slag system, the method can support process monitoring and may provide indirect indicators related to changes in surface agitation or foaming tendency, enabling structured data-driven analysis. The framework thus provides a practical bridge between cold-model experiments, high-temperature measurements, multiphase modeling and industrial TSL operation.
Förderung
- BMBF, Germany
Zitieren
APA
Kandalam, A., Reuter, M. A., Stelter, M., Richter, A., Kupsch, C., & Charitos, A. (2026). Acoustic and Inertial Sensor Techniques for Top Submerged Lance (TSL) Technology: A Practical Framework for Characterizing Bubble Dynamics Under High-Temperature Conditions. Metals, 16(5), 519. https://doi.org/10.3390/met16050519
Vancouver
Kandalam A, Reuter MA, Stelter M, Richter A, Kupsch C, Charitos A. Acoustic and Inertial Sensor Techniques for Top Submerged Lance (TSL) Technology: A Practical Framework for Characterizing Bubble Dynamics Under High-Temperature Conditions. Metals. 2026;16(5):519. doi:10.3390/met16050519
BibTeX
@article{Kandalam2026,
author = {Kandalam, Avinash and Reuter, Markus Andreas and Stelter, Michael and Richter, Andreas and Kupsch, Christian and Charitos, Alexandros},
title = {Acoustic and Inertial Sensor Techniques for Top Submerged Lance (TSL) Technology: A Practical Framework for Characterizing Bubble Dynamics Under High-Temperature Conditions},
journal = {Metals},
year = {2026},
volume = {16},
number = {5},
pages = {519},
doi = {10.3390/met16050519}
}
EUVIMED