Thermodynamic Evaluation of a Triple-Pass Reverse Osmosis Seawater Desalination Plant: Energy and Exergy Perspectives
Membranes · 01.07.2026 · 16 (7) · 227
DOI: 10.3390/membranes16070227 ↗Kurz gefasst
Fachartikel in der Zeitschrift Membranes, online erschienen am 01.07.2026. Verfasst von Abdulrahman S Almutairi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Power and Refrigeration Technology, College of Technological Studies, Public Authority for Applied Education and Training, S…. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Energy and exergy analyses were conducted on a triple-pass seawater reverse osmosis desalination system to evaluate thermodynamic performance and identify primary sources of irreversibility. A comprehensive simulation model, developed in IPSEpro (Version 7.0) and validated against manufacturer data, demonstrated strong agreement with the reported values. Exergetic efficiency of the reverse osmosis (RO) units increased across the passes, from 57% in the first pass to 80% and 78% in the second and third passes, respectively, while exergy destruction decreased correspondingly from approximately 375 kW in the first pass to 120 kW and 130 kW in the second and third passes. The pumping system, particularly the main high-pressure pump, was responsible for 49% of total exergy destruction, followed by the first RO unit at 23%. The impacts of feed water temperature, high-pressure pump pressure, and water recovery ratio (RC) on exergetic efficiency, specific energy consumption, and permeate flow rate were systematically assessed. Increasing the feed water temperature from 15 °C to 33 °C enhanced exergetic efficiency from 27.8% to 29.9% and reduced total exergy destruction from 1622 to 1582 kW, supporting the integration of hybrid RO-thermal desalination systems. The first-pass recovery ratio emerged as the most influential operational parameter overall, with exergetic efficiency rising from 25.1% to 33.7% as RC1 increased from 0.35 to 0.60. Analysis of the overall recovery ratio identified RC = 0.39 as a practical operating target that balances specific energy consumption of 4.05 kWh/m3 and exergy destruction of 1700 kW, offering the most favourable compromise between energy efficiency and thermodynamic performance. The results presented here provide practical guidance and recommendations for the optimization of the performance of large-scale multi-pass reverse osmosis seawater desalination plants.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Power and Refrigeration Technology, College of Technological Studies, Public Authority for Applied Education and Training, Shuwaikh, P.O. Box 42325, Kuwait City 70654, Kuwait.
- Department of Mechanical Engineering, Faculty of Engineering, King Abdulaziz University, P.O. Box 80204, Jeddah 21589, Saudi Arabia.
- Center of Excellence in Desalination Technology, King Abdulaziz University, P.O. Box 80200, Jeddah 21589, Saudi Arabia.
ORCID-Profile: Hani Abulkhair
Zitieren
APA
Almutairi, A. S., Abulkhair, H., Almokmesh, S. F., & Alotaibi, T. E. (2026). Thermodynamic Evaluation of a Triple-Pass Reverse Osmosis Seawater Desalination Plant: Energy and Exergy Perspectives. Membranes, 16(7), 227. https://doi.org/10.3390/membranes16070227
Vancouver
Almutairi AS, Abulkhair H, Almokmesh SF, Alotaibi TE. Thermodynamic Evaluation of a Triple-Pass Reverse Osmosis Seawater Desalination Plant: Energy and Exergy Perspectives. Membranes. 2026;16(7):227. doi:10.3390/membranes16070227
BibTeX
@article{Almutairi2026,
author = {Almutairi, Abdulrahman S and Abulkhair, Hani and Almokmesh, Saad F and Alotaibi, Talal E},
title = {Thermodynamic Evaluation of a Triple-Pass Reverse Osmosis Seawater Desalination Plant: Energy and Exergy Perspectives},
journal = {Membranes},
year = {2026},
volume = {16},
number = {7},
pages = {227},
doi = {10.3390/membranes16070227}
}