EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pilot Plant Test of Single-Pass Electrodialysis Reversal System

Marian Turek iD, Ewa Bernacka iD, Krzysztof Mitko iD

Membranes · 25.03.2026 · 16 (4) · 114

DOI: 10.3390/membranes16040114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Membranes, online erschienen am 25.03.2026. Verfasst von Marian Turek und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Inorganic, Analytical Chemistry and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, ul. B. Krzywoustego 6, 4…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Centre for Research and Development, Polish National Centre for Research and Development https://ror.org/05pwfyy15.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasing the recovery in electrodialysis desalination may be achieved using a single-pass operation at different linear flow velocity values in the diluate and concentrate compartments. The risk of inner leakage as well as membrane bulging and damage can be minimized by controlling the pressure difference between the diluate and concentrate compartments. This solution has been tested in a pilot plant for initial demineralization of river water using an electrodialyzer of our own design. Both under- and overlimiting regimes have been tested, as well as long work cycles between electrode polarity reversals. Water with a conductivity of about 500 µS/cm was desalinated at a recovery of 70–75%, and the desalination degree was 75–96%. It was also found that the unit cost could be decreased by 52% compared to a commercial solution when the diluate conductivity was 74.3 μS/cm. A deep demineralization, from 511 μS/cm down to 17.9 μS/cm in a single-stage EDR or 8.52 μS/cm in a two-stage EDR, was also confirmed experimentally at the pilot scale.

Schlagwörter

Stichwörter der Autor:innen

electrodialysis reversalpilot plant testsingle-pass mode

Autor:innen und Institutionen

  • Department of Inorganic, Analytical Chemistry and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, ul. B. Krzywoustego 6, 44-100 Gliwice, Poland.
  • PolymemTech Sp. z o.o., ul. Królewska 18, 00-103 Warszawa, Poland.

ORCID-Profile: Marian Turek, Ewa Bernacka, Krzysztof Mitko

Förderung

  • National Centre for Research and Development
  • Polish National Centre for Research and Development https://ror.org/05pwfyy15

Zitieren

APA

Turek, M., Bernacka, E., & Mitko, K. (2026). Pilot Plant Test of Single-Pass Electrodialysis Reversal System. Membranes, 16(4), 114. https://doi.org/10.3390/membranes16040114

Vancouver

Turek M, Bernacka E, Mitko K. Pilot Plant Test of Single-Pass Electrodialysis Reversal System. Membranes. 2026;16(4):114. doi:10.3390/membranes16040114

BibTeX
@article{Turek2026,
  author = {Turek, Marian and Bernacka, Ewa and Mitko, Krzysztof},
  title = {Pilot Plant Test of Single-Pass Electrodialysis Reversal System},
  journal = {Membranes},
  year = {2026},
  volume = {16},
  number = {4},
  pages = {114},
  doi = {10.3390/membranes16040114}
}
Kostenlos starten →