Removal of Aggregates During Bispecific Antibody Purification Using Hydrophobic Interaction Chromatography
Membranes · 01.10.2025 · 15 (10) · 299
DOI: 10.3390/membranes15100299 ↗Kurz gefasst
Fachartikel in der Zeitschrift Membranes, online erschienen am 01.10.2025. Verfasst von Puya Zhao und 2 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai AsymChem Biotechnology Co., Ltd., Building 8, No.12, Lane 855, Jinzheng Road, Jinshan Industrial Park, Shanghai 201507, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In the production of recombinant antibody/Fc-fusion proteins using mammalian cells, many aggregates often form alongside the target proteins, particularly with bispecific antibodies. To ensure the safety of biological products, it is essential to control the amount of aggregates within a specific range. A traditional downstream process typically involves using Protein A (ProA) resin to capture the target antibody, followed by two polishing steps to ensure purity; for instance, using an anion exchange chromatography (AEX) in flow-through mode and a cation exchange chromatography (CEX) in binding–elution mode. In this study, we choose a Dual Action Fab (DAF), which can bind two antigens and is prone to aggregation when expression in CHO (Chinese Hamster Ovary) cells. We introduce hydrophobic interaction membrane chromatography (HIMC) operating in flow-through mode, which enhances production efficiency while reducing costs and the risks associated with column packing. We evaluated the impact of the operating buffer system, as well as the pH and conductivity of the loading samples, on aggregate removal using HIMC. Additionally, we investigated the mechanism of aggregate binding and found that loading conditions had a limited impact on this process. Overall, our findings indicate that employing HIMC can achieve a 20% reduction in aggregate levels. These results demonstrate that HIMC in flow-through mode is an effective and robust approach for reducing aggregates during antibody purification.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Shanghai AsymChem Biotechnology Co., Ltd., Building 8, No.12, Lane 855, Jinzheng Road, Jinshan Industrial Park, Shanghai 201507, China.
ORCID-Profile: Puya Zhao
Zitieren
APA
Zhao, P., Qi, Y., & Gao, K. (2025). Removal of Aggregates During Bispecific Antibody Purification Using Hydrophobic Interaction Chromatography. Membranes, 15(10), 299. https://doi.org/10.3390/membranes15100299
Vancouver
Zhao P, Qi Y, Gao K. Removal of Aggregates During Bispecific Antibody Purification Using Hydrophobic Interaction Chromatography. Membranes. 2025;15(10):299. doi:10.3390/membranes15100299
BibTeX
@article{Zhao2025,
author = {Zhao, Puya and Qi, Yue and Gao, Kai},
title = {Removal of Aggregates During Bispecific Antibody Purification Using Hydrophobic Interaction Chromatography},
journal = {Membranes},
year = {2025},
volume = {15},
number = {10},
pages = {299},
doi = {10.3390/membranes15100299}
}