EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A New Method for Quantitative Evaluation Concentration Polarization Under Different Conditions for the Forward Osmosis Process

Ping Xiao, Liang Liu

Membranes · 25.07.2025 · 15 (8) · 223

DOI: 10.3390/membranes15080223 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Membranes, online erschienen am 25.07.2025. Verfasst von Ping Xiao und 1 weiteren Autor:innen. Beteiligte Einrichtung: Green Intelligence Environmental School, Yangtze Normal University, No. 16 Juxian Road, Fuling District, Chongqing 408100, China. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Chongqing Municipal Education Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Concentration polarization (CP) is one of the inherent problems that lowers the operating performance of forward osmosis (FO) membranes. Therefore, a quantitative evaluation of CP is vital to understand its impact on the FO process. This study systematically investigated the influences of different CPs on the osmotic pressure drop across the membrane under different conditions by using the water transmission coefficient, ηWT, defined as the ratio of the measured water flux to the theoretical water flux. The results showed that ηWT decreased with an increase in the concentration gradient between the draw solution (DS) and the feed solution (FS) under different conditions. The proportions of osmotic pressure drop caused by dilutive internal concentration polarization (ICP) increased, while those caused by concentrative external concentration polarization (ECP) decreased, in different types of DSs in FO mode. Both ECP and ICP were found to be capable of reducing osmotic pressure. However, the internal CP had the dominant influence. To better understand the adverse effects of CP, using an organic FS provided greater insight than using deionized (DI) water as the FS. As the FS concentration increased, the water flux reduced, and the adverse effects of CP worsened. CaCl2 led to a greater reduction in water transfer efficiency than NaCl when used as the DS. In comparison to FO mode, pressure-retarded osmosis (PRO) mode led to greater pure water flux and flux decline. In FO mode, both the proportion of dilutive ICP and the ηWT decreased, while the proportion of concentrative ECP increased over time. However, in PRO mode, the proportions of dilutive ECP and concentrative ICP increased, and ηWT gradually decreased. Dilutive ICP had a significant negative effect on osmotic pressure in the former, while dilutive ECP was dominant in the latter.

Schlagwörter

Stichwörter der Autor:innen

forward osmosisosmotic pressure differencewater fluxwater transmission coefficient

Autor:innen und Institutionen

  • Green Intelligence Environmental School, Yangtze Normal University, No. 16 Juxian Road, Fuling District, Chongqing 408100, China.

Förderung

  • National Natural Science Foundation of China
  • Chongqing Municipal Education Commission

Zitieren

APA

Xiao, P., & Liu, L. (2025). A New Method for Quantitative Evaluation Concentration Polarization Under Different Conditions for the Forward Osmosis Process. Membranes, 15(8), 223. https://doi.org/10.3390/membranes15080223

Vancouver

Xiao P, Liu L. A New Method for Quantitative Evaluation Concentration Polarization Under Different Conditions for the Forward Osmosis Process. Membranes. 2025;15(8):223. doi:10.3390/membranes15080223

BibTeX
@article{Xiao2025,
  author = {Xiao, Ping and Liu, Liang},
  title = {A New Method for Quantitative Evaluation Concentration Polarization Under Different Conditions for the Forward Osmosis Process},
  journal = {Membranes},
  year = {2025},
  volume = {15},
  number = {8},
  pages = {223},
  doi = {10.3390/membranes15080223}
}
Kostenlos starten →