Improving the Accuracy of Permeability Data to Gain Predictive Power: Assessing Sources of Variability in Assays Using Cell Monolayers
Membranes · 14.07.2024 · 14 (7) · 157
DOI: 10.3390/membranes14070157 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Membranes, online erschienen am 14.07.2024. Verfasst von Cristiana L Pires und 1 weiteren Autor:innen. Beteiligte Einrichtung: Coimbra Chemistry Center-Institute of Molecular Sciences (CQC-IMS), University of Coimbra, 3004-535 Coimbra, Portugal. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 237 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, Portuguese Foundation for Science and Technology (FCT), Portuguese funds via FCT.
Abstract (Originalsprache)
The ability to predict the rate of permeation of new compounds across biological membranes is of high importance for their success as drugs, as it determines their efficacy, pharmacokinetics, and safety profile. In vitro permeability assays using Caco-2 monolayers are commonly employed to assess permeability across the intestinal epithelium, with an extensive number of apparent permeability coefficient (Papp) values available in the literature and a significant fraction collected in databases. The compilation of these Papp values for large datasets allows for the application of artificial intelligence tools for establishing quantitative structure–permeability relationships (QSPRs) to predict the permeability of new compounds from their structural properties. One of the main challenges that hinders the development of accurate predictions is the existence of multiple Papp values for the same compound, mostly caused by differences in the experimental protocols employed. This review addresses the magnitude of the variability within and between laboratories to interpret its impact on QSPR modelling, systematically and quantitatively assessing the most common sources of variability. This review emphasizes the importance of compiling consistent Papp data and suggests strategies that may be used to obtain such data, contributing to the establishment of robust QSPRs with enhanced predictive power.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Coimbra Chemistry Center-Institute of Molecular Sciences (CQC-IMS), University of Coimbra, 3004-535 Coimbra, Portugal.
- Chemistry Department, Faculty of Science and Technology, University of Coimbra, 3004-535 Coimbra, Portugal.
ORCID-Profile: Cristiana L Pires, Maria João Moreno
Förderung
- Fundação para a Ciência e Tecnologia
- Portuguese Foundation for Science and Technology (FCT)
- Portuguese funds via FCT
Zitieren
APA
Pires, C. L., & Moreno, M. J. (2024). Improving the Accuracy of Permeability Data to Gain Predictive Power: Assessing Sources of Variability in Assays Using Cell Monolayers. Membranes, 14(7), 157. https://doi.org/10.3390/membranes14070157
Vancouver
Pires CL, Moreno MJ. Improving the Accuracy of Permeability Data to Gain Predictive Power: Assessing Sources of Variability in Assays Using Cell Monolayers. Membranes. 2024;14(7):157. doi:10.3390/membranes14070157
BibTeX
@article{Pires2024,
author = {Pires, Cristiana L and Moreno, Maria João},
title = {Improving the Accuracy of Permeability Data to Gain Predictive Power: Assessing Sources of Variability in Assays Using Cell Monolayers},
journal = {Membranes},
year = {2024},
volume = {14},
number = {7},
pages = {157},
doi = {10.3390/membranes14070157}
}
EUVIMED