Effect of Operating Parameters on the Performance of Integrated Fixed-Film Activated Sludge for Wastewater Treatment
Membranes · 28.07.2023 · 13 (8) · 704
DOI: 10.3390/membranes13080704 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Membranes, online erschienen am 28.07.2023. Verfasst von Sharjeel Waqas und 8 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar 32610, Malaysia. Die Arbeit wurde bisher 65-mal zitiert (Crossref) und nennt 131 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Jeddah, Saudi Arabia, Universiti Teknologi PETRONAS, Malaysia.
Abstract (Originalsprache)
Integrated fixed-film activated sludge (IFAS) is a hybrid wastewater treatment process that combines suspended and attached growth. The current review provides an overview of the effect of operating parameters on the performance of IFAS and their implications for wastewater treatment. The operating parameters examined include hydraulic retention time (HRT), solids retention time (SRT), dissolved oxygen (DO) levels, temperature, nutrient loading rates, and aeration. Proper control and optimization of these parameters significantly enhance the treatment efficiency and pollutant removal. Longer HRT and appropriate SRT contribute to improved organic matter and nutrient removal. DO levels promote the growth of aerobic microorganisms, leading to enhanced organic matter degradation. Temperature influences microbial activity and enzymatic reactions, impacting treatment efficiency. Nutrient loading rates must be carefully managed to avoid system overload or inhibition. Effective aeration ensures uniform distribution of wastewater and biofilm carriers, optimizing contact between microorganisms and pollutants. IFAS has been used in water reuse applications, providing a sustainable and reliable water source for non-potable uses. Overall, IFAS has proven to be an effective and efficient treatment process that can provide high-quality effluent suitable for discharge or reuse. Understanding the effects of these operating parameters helps to optimize the design and operation for efficient wastewater treatment. Further research is needed to explore the interactions between different parameters, evaluate their impact under varying wastewater characteristics, and develop advanced control strategies for improved performance and sustainability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Chemical Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar 32610, Malaysia.
- Department of Chemical Engineering, Universitas Pertamina, Simprug, Jakarta Selatan 12220, Indonesia.
- Department of Chemical Engineering, University of Jeddah, Jeddah 23890, Saudi Arabia.
- Department of Civil and Environmental Engineering, College of Engineering, University of Jeddah, Jeddah 23890, Saudi Arabia.
ORCID-Profile: Sharjeel Waqas, Noorfidza Yub Harun, Nonni Soraya Sambudi, Loai Alkhattabi
Förderung
- University of Jeddah, Saudi Arabia
- Universiti Teknologi PETRONAS, Malaysia
Zitieren
APA
Waqas, S., Harun, N. Y., Sambudi, N. S., Abioye, K. J., Zeeshan, M. H., Ali, A., Abdulrahman, A., Alkhattabi, L., & Alsaadi, A. S. (2023). Effect of Operating Parameters on the Performance of Integrated Fixed-Film Activated Sludge for Wastewater Treatment. Membranes, 13(8), 704. https://doi.org/10.3390/membranes13080704
Vancouver
Waqas S, Harun NY, Sambudi NS, Abioye KJ, Zeeshan MH, Ali A, et al. Effect of Operating Parameters on the Performance of Integrated Fixed-Film Activated Sludge for Wastewater Treatment. Membranes. 2023;13(8):704. doi:10.3390/membranes13080704
BibTeX
@article{Waqas2023,
author = {Waqas, Sharjeel and Harun, Noorfidza Yub and Sambudi, Nonni Soraya and Abioye, Kunmi Joshua and Zeeshan, Muhammad Hamad and Ali, Abulhassan and Abdulrahman, Aymn and Alkhattabi, Loai and Alsaadi, Ahmad S},
title = {Effect of Operating Parameters on the Performance of Integrated Fixed-Film Activated Sludge for Wastewater Treatment},
journal = {Membranes},
year = {2023},
volume = {13},
number = {8},
pages = {704},
doi = {10.3390/membranes13080704}
}
EUVIMED